Datcon DT7200 Series User Manual page 10

Intrinsically safe pressure transmitters
Table of Contents

Advertisement

Ambient conditions:
- operating temperature range:
Type
Seal
PTFE, EPDM
DT7200 L
FKM
FFKM
PTFE, EPDM
DT7200 M
FKM
FFKM
PTFE
EPDM
DT7200 H
FKM
FFKM
- storing temperature range:
- shock resistance:
Class of intrinsical safety:
DT7200 L
DT7200 M
DT7200 H
Certificate:
Safety data:
10
Ambient temperature
-25 °C ≤ Ta ≤ 60 °C
-15 °C ≤ Ta ≤ 60 °C
-20 °C ≤ Ta ≤ 60 °C
-25 °C ≤ Ta ≤ 70 °C
-15 °C ≤ Ta ≤ 70 °C
-20 °C ≤ Ta ≤ 70 °C
-25 °C ≤ Ta ≤ 70 °C
-25 °C ≤ Ta ≤ 70 °C
-15 °C ≤ Ta ≤ 70 °C
-20 °C ≤ Ta ≤ 70 °C
-25 °C – +70 °C
max. 20 g
II 1 G Ex ia IIC T4 Ga
II 1 G Ex ia IIC T4 Ga
II 1 G Ex ia IIC T4...T3 Ga
BKI15ATEX0037 X
BKI15ATEX0037 X/1
BKI15ATEX0037 X/2
U
: 28 V
I
: 100 mA
i
i
: 506 H
C
: 37 nF
L
i
i
Temperature of medium
-25 °C ≤ Tp ≤ 70 °C
-15 °C ≤ Tp ≤ 70 °C
-20 °C ≤ Tp ≤ 70 °C
-25 °C ≤ Tp ≤ 90 °C
-15 °C ≤ Tp ≤ 90 °C
-20 °C ≤ Tp ≤ 90 °C
T4: -25 °C ≤ Tp ≤ 130 °C
T3: -25 °C ≤ Tp ≤ 140 °C
T4: -25 °C ≤ Tp ≤ 130 °C
T4: -15 °C ≤ Tp ≤ 130 °C
T3: -15 °C ≤ Tp ≤ 140 °C
T4: -20 °C ≤ Ta ≤ 130 °C
T3: -20 °C ≤ Tp ≤ 140 °C
P
: 0.7 W
i

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dt7000Dt7100Dt7100hDt7200lDt7200mDt7200h