Datcon DT1012 IP Operating Instructions Manual

Temperature / resistance / potentiometer transmitter

Advertisement

Quick Links

DT1012 IP (PS)
Temperature / Resistance / Potentiometer Transmitter
Operating Instructions

Advertisement

Table of Contents
loading

Summary of Contents for Datcon DT1012 IP

  • Page 1 DT1012 IP (PS) Temperature / Resistance / Potentiometer Transmitter Operating Instructions...
  • Page 2: Table Of Contents

    DT1012 IP Contents . About this document..............4 1.1. Function....................4 1.2. Target group..................4 1.3. Symbolism used .................. 4 2. For your safety................5 2.1. Authorized personnel................5 2.2. Appropriate use ................... 5 2.3. Warning about misuse ................. 5 2.4. General safety instructions ..............5 2.5.
  • Page 3 DT1012 IP Setting-up................21 7.1. About the setting in general ............... 21 7.2. Input signal source setting ..............22 7.2.1. Pt temperature setting ..............23 7.2.2. Potentiometer setting..............24 7.2.3. Scaled potentiometer setting ............25 7.2.4. Resistor setting................26 7.3. Analogue output setting ..............27 7.4.
  • Page 4: About This Document

    1.1. Function This operating instructions manual has all the information you need for quick set-up and safe operation of DT1012 IP. Please read this manual before you start setup. 1.2. Target group This operating instructions manual is directed to trained personnel.
  • Page 5: For Your Safety

    2.5. CE conformity A DT1012 IP (PS) is in conformity with the provisions of the following standards: EN IEC 61326-1 (EMC) EN 55011 (EMC)
  • Page 6: Product Description

    DT1012 IP 3. Product description 3.1. Delivery configuration Delivered items The scope of delivery encompasses: • DT1012 IP (PS) • documentation: this operating instructions Certificate mini USB (5 pin) – USB A cable Configuration software CD 3.2. Type designation 20221107-V0...
  • Page 7: Principle Of Operation

    Area of application A Pt100 / Pt500 / Pt1000 temperature sensor, linear resistor or potentiometer can be connected to the input of the DT1012 IP… Temperature / Resistance / Potentiometer Transmitter. When a Pt temperature sensor is connected, the output signal is...
  • Page 8: Setting

    Power supply The (PS) can be ordered with two types of power supply: DT1012 IP: 24 VDC DT1012 IP PS: 230 V AC/DC 3.4. Setting After the instrument is connected to the power supply — see 6.1. First power on with factory settings according to chapter —...
  • Page 9: Indicator Leds, Usb Connector

    10.1. Technical specification, as described under the title: Environmental conditions. The packaging of DT1012 IP consist of environment-friendly, recyclable cardboard is used to protect the instrument against the impacts of normal stresses occurring during transportation. The corrugated cardboard box is made from environment-friendly, recyclable paper.
  • Page 10: Mounting

    DT1012 IP 4. Mounting 4.1. General instructions The instrument should be installed in a cabinet with sufficient IP protection, where the operating conditions are in accordance with chapter 10.1. Technical specification, as described under the title: Ambient conditions Mounting position The instruments are designed in a housing for mounting on TS-35 rail.
  • Page 11: Mounting

    DT1012 IP 4.3. Mounting The following figure shows the mounting procedures (fixing on the rail): Mounting on the rail No tools are required for installation. 1. In the position shown in the figure, place the fixing groove of the instrument on the upper edge of the rail (step 1 in figure).
  • Page 12: Connecting

    DT1012 IP 5. Connecting 5.1. Preparing the connection Always observe the following safety instructions: • The connection must be carried out by trained and authorized personnel only! • Connect only in the complete absence of supply voltage • Use only a screwdriver with appropriate head...
  • Page 13: Connecting Sensor / Resistor / Potentiometer To The Input

    DT1012 IP 5.2. Connecting sensor / resistor / potentiometer to the input The following figure shows the wiring plan, connecting the sensor / resistor / potentiometer to the input: Wiring plan, connecting the sensor / resistor / potentiometer to the...
  • Page 14 DT1012 IP 1. Loosen terminal screws. 2. Insert the wire ends into the open terminals according to the wiring plan. 3. Screw the terminal in. 4. Check the hold of the wires in terminals by pulling on them firmly. Checking the...
  • Page 15: Connecting The Current Output To The Signal Processor Unit

    DT1012 IP 5.3. Connecting the current output to the signal processor unit The following figure shows the wiring plan, connecting the passive current output to the signal processing unit: Wiring plan, connecting the current output to the signal processing unit...
  • Page 16: Connecting The Instrument To Dc Power Supply

    DT1012 IP 5.4. Connecting the instrument to DC power supply The following figure shows the wiring plan, connecting the instrument to DC power supply: Wiring plan connecting to DC power supply Polarity is indifferent 1. Loosen terminal screws. 2. Insert the wire ends into the open terminals according to the wiring plan.
  • Page 17: Connecting The Instrument To 230 V Ac/Dc Power Supply

    DT1012 IP Connecting the instrument to 230 V AC/DC power supply The following figure shows the wiring plan, connecting the instrument to 230 V AC/DC power supply: (note the information about the installation overcurrent protection see chapter 10.1. Technical specification)
  • Page 18: Connecting To Pc Via Usb Cable

    DT1012 IP 5.6. Connecting to PC via USB cable The following figure shows the wiring plan, connecting the instrument to The PC: 1. Open the front cover of the instrument (from bottom to top). 2. To communicate with the configuration program, plug the included USB cable (USB-B mini, 5-pin connector) into the "USB"...
  • Page 19: The First Power On, Indicators

    DT1012 IP 6. The first power on, indicators 6.1. First power on The instrument is operational immediately after switching on the power supply (see: previous chapter). The factory settings are as follows: • Input signal source: Pt temperature sensor •...
  • Page 20: Indicators

    DT1012 IP 6.2. Indicators The following figure shows the front panel of the instrument with the USB connector and indicators: (2) "error" indicator (LED located on the front panel, under the USB connector), which indicates the error status with a red, flashing light.
  • Page 21: Setting-Up

    DT1012 IP 7. Setting-up 7.1. About the setting in general Necessary tools Setup requires the following: • mini USB (5 pin) - USB A cable (accessory) • PIC32MM.exe configuration software (accessory) • PC, with Windows Operation System and USB port...
  • Page 22: Input Signal Source Setting

    DT1012 IP 7.2. Input signal source setting Signal source connected to the input of the instrument: • Pt temperature sensor • Potentiometer • Scaled potentiometer • Resistor [Factory default: Pt temperature sensor] Setup steps 1. Click the "Pt / Potentiometer / R” button in the ”INPUT” field.
  • Page 23: Pt Temperature Setting

    DT1012 IP 7.2.1. Pt temperature setting 3. Select the wire number you want to use. 4. Select the measurement time you want to use. 5. If you want to correct the error of the Pt sensor, you can do it at 3 points.
  • Page 24: Potentiometer Setting

    DT1012 IP 7.2.2. Potentiometer setting 3. Select the wire number you want to use. 4. Select the measurement time you want to use. 5. Set the potentiometer to initial value. 6. Click the "0%" button. 7. Set the potentiometer to final value.
  • Page 25: Scaled Potentiometer Setting

    DT1012 IP 7.2.3. Scaled potentiometer setting 3. Select the wire number you want to use. 4. Select the measurement time you want to use. 5. Set the potentiometer to initial value. 6. Click the "0%" button. Set the potentiometer to final value.
  • Page 26: Resistor Setting

    DT1012 IP 7.2.4. Resistor setting 3. Select the wire number you want to use. 4. Select the measurement time you want to use. 5. Store the settings by clicking the "Write to instrument" button. 6. Close the settings window by clicking the "Exit (Esc)" button.
  • Page 27: Analogue Output Setting

    DT1012 IP 7.3. Analogue output setting Used to set the analogue output parameters as: Function Analogue output type: 4-20mA / 0-20mA / 0-10V / 0-5V / 2-10V Error indication: None / Yes Location of error indication (for 4-20 mA): below 4 mA / above 20 mA...
  • Page 28: Factory Default Resetting

    DT1012 IP 7.4. Factory default resetting Function Used to restore factory settings. Displays the factory default value of the settings in the opened settings window. This will not be set in the instrument yet, only if you click on the "Write to instrument" button. If you do not want to set these values in the instrument, exit by pressing the "Exit (Esc)"...
  • Page 29: Display Measuring Values

    DT1012 IP 7.6. Display measuring values Function The configuration program displays the value of temperature, potentiometer position or resistance measured at the input. These data are for diagnostic purposes. This allows the user to check the instrument and the settings.
  • Page 30: Error Display

    (in the upper right corner of the configuration program window). Error code "1": Serious error. The error can only be resolved at the Datcon service center. If the instrument only receives power from the USB port, ”Error 1” is still displayed, because in this case the input module of the instrument does not receive power, so the instrument perceives it as faulty.
  • Page 31: Fault Rectification, Repair

    8.2. Repairing There is no user repairable part inside the instrument. In accordance with Point 2.1. Authorized personnel: For safety and warranty reasons, any internal work on the instrument must be carried out only by DATCON personnel. 20221107-V0...
  • Page 32: Dismounting

    DT1012 IP 9. Dismounting 9.1. Dismounting procedure The following figure shows the dismounting procedures: Dismounting from the rail The dismounting procedure needs a screwdriver for slotted screws. 1. Switch off the power supply 2. Disconnect all wires. 3. Put the screwdriver end into the fixing assembly’s hole (figure step 1.).
  • Page 33: Appendix

    DT1012 IP 10. Appendix 10.1. Technical specification Input parameters Input signal: When ordering, you can choose one of the following measuring sensor input type: Pt100 / Pt500 / Pt1000 Resistor / Potentiometer (max. 400 Ω or 4 kΩ) Connection: 4 / 3 / 2 wires Measuring current: 880 μA @ Pt100 / 250 μA @ Pt500, Pt1000)
  • Page 34 DT1012 IP Power supply Power supply: DT1012 IP 24 VDC ±10%, 1.6 W DT1012 IP PS 230 V AC/DC ±10%, 3.8 VA (2.4 W) Overvoltage category: CAT II. Installation overcurrent protection: 4 A (B) Ambient conditions Operating temperature range: 0-60 °C * Storage temperature range: -20 - +70 °C...
  • Page 35 DT1012 IP 20221107-V0...

Table of Contents