Diaphragm pump N 816
Conditions
Translation of original Operating and Installation Instructions, english, KNF 312649-312652 02/23
9.
Servicing
9.1. Servicing schedule
Component
Pump
Tube connection
Diaphragm and valve
plates/sealings
Tab. 13
9.2. Cleaning
When cleaning, make sure that no liquids enter the inside of
the housing.
9.2.1. Flushing pump
Flush the pump under atmospheric conditions some minutes
with air (or, if necessary for safety reasons, with an inert gas)
prior to switch-off.
9.2.2. Cleaning pump
Motor disconnected from mains and de-energized
Health hazard due to dangerous substances in the
pump!
Depending on the substances transferred, caustic
burns or poisoning are possible.
WARNING
Wear protective clothing if necessary, e.g. pro-
tective gloves.
Clean pump with suitable measures.
Danger of burns from hot pump parts
The pump head or motor may be hot even after the
pump has been shut off.
CAUTION
Allow the pump to cool off after operation.
As far as possible, clean the parts with a dry cloth. Solvents
should not be used as they can attack the plastics, and syn-
thetic rubber parts.
If compressed air is available, blow out the components.
Servicing interval
Regular inspection for external
-
damage or leaks
Regular inspection for external
-
damage or leaks
Replace if pump's pressure or flow
-
rate change without apparent rea-
son
Replace at the latest, when pump
-
output decreases
Servicing
39