Velocity And Filter Look-Up Tables - Primayer ADS Eureka2R User Manual

Leak noise correlator
Table of Contents

Advertisement

Velocity and Filter Look-Up Tables

The Eureka2R uses the values in the table below as default values based on
the pipe material, pipe diameter, and type of sensor used. These defaults may
be adjusted as described in this manual. The abbreviations representing the
individual materials are used by Eureka. When using an Accelerometer -
Hydrophone sensor combination, select the default filter settings for
Hydrophone - Hydrophone.
Diameter in Inches (mm)
AC
<3.94 (<100)
Asbestos
Cement
3.94 to 7.87 (100 to 200)
8.27 to 13.78 (210 to 350)
14.17 to 19.69 (360 to 500)
20.08 to 31.50 (510 to 800)
>31.50 (>800)
Diameter in Inches (mm)
CI
Cast Iron
<3.94 (<100)
3.94 to 7.87 (100 to 200)
8.27 to 11.81 (210 to 300)
12.20 to 15.75 (310 to 400)
16.14 to 23.62 (410 to 600)
24.02 to 31.50 (610 to 800)
>311.50 (>800)
Diameter in Inches (mm)
CON
<19.69 (<500)
Concrete
19.69 to 29.53 (500 to 750)
29.92 to 39.37 (760 to 1000)
39.76 to 59.06 (1010 to 1500)
>59.06 (>1500)
ADS Eureka2R Leak Noise Correlator User Manual
Velocity in Feet Per
Filters (Hz)
Second (m/s)
Mic/Mic
3543 (1080)
100 to 1000
3314 (1010)
3215 (980)
3150 (960)
3051 (930)
2953 (900)
Velocity in Feet Per
Filters (Hz)
Second (m/s)
Mic/Mic
4199 (1280)
100 to 2000
4003 (1220)
3806 (1160)
3675 (1120)
3609 (1100)
3543 (1080)
3445 (1050)
Velocity in Feet Per
Filters (Hz)
Second (m/s)
Mic/Mic
3806 (1160)
100 – 1000
3642 (1110)
3478 (1060)
3379 (1030)
3281 (1000)
Filters (Hz)
Hydro/Hydro
25 to 500
Filters (Hz)
Hydro/Hydro
25 to 1000
Filters (Hz)
Hydro/Hydro
25 - 500
37

Advertisement

Table of Contents
loading

Related Products for Primayer ADS Eureka2R

Table of Contents