Chapter 5 Appendix; Specifications - Primayer ADS Eureka2R User Manual

Leak noise correlator
Table of Contents

Advertisement

C H A P T E R 5
Appendix
This appendix contains the following information pertaining to the ADS
Eureka2R Leak Noise Correlator:
Technical Specifications
System Components
Optional Equipment
Velocity and Filter Lookup Tables Appendix A – System Components
and Specifications

Specifications

Measurement
Method
Equivalent
Time Delay
Maximum
Distance
Distance
Resolution
Filters
Sensors
Inputs
Radio System
Storage/
Results
ADS Eureka2R Leak Noise Correlator User Manual
Cross-correlation
+/– 12 seconds
Iron Pipe: 9.9 miles (16 km) – theoretical
Plastic Pipe: 2.2 miles (3.5 km) – theoretical
4 inches (0.1 m) using zoom function at long distances
Low: 3, 25, 100, 250, 500 Hz
High: 100, 250, 500, 1000, 2000 Hz
Accelerometer, Hydrophone, Ground Microphone
Radio or direct (blue channel)
Frequency: 458 MHz nominal (other frequencies available)
Power: 500 mW (other power outputs available)
Memory: 30 correlations (typical) including correlation function
Output: Recall to view or print
Printer: Parallel interface