ADS Eureka2R Leak Noise Correlator User Manual
Fast Track correlation screen
If the pipe material remains constant, you only need to change the various pipe
lengths between each correlation run.
Fast Track does not include a function for saving files to memory. This can
occur only by setting the correlation to the advanced mode before
commencing correlation.

Recharging the Eureka

Connecting the correlator to the charger illuminates the ON button. If the
charger is not ready (i.e., it is charging another piece of equipment), the button
will flash continuously; if the charger is ready, the screen display will appear
and the button will extinguish. For a fully discharged battery, it may take
some time for the display to appear.
The screen displays the battery charge similar to a fuel gauge. Therefore, the
amount of the charge is always visible.
The battery icon displays a 1 when the correlator is on fast charge, 2 when the
correlator is receiving a top-up charge, and 3 when the charge is complete.
When fully discharged, the correlator requires approximately 1 hour to obtain
a 75% charge; top-up charging occurs at a slower rate to ensure optimum
battery life.
The correlator automatically turns off 15 minutes after the charger is
disconnected. A warning beep sounds for the last 2 minutes of this timeout
cycle.