Operation manual GENO-mat filter system F 500/600/610 A; three-phase current/AC with GENO-BW-tronic Edition June 2020 Order no. 240 962-inter_105...
Filter system GENO-mat F 500/600/610 three-phase current/AC Table of contents A General information ............. 5 1 Preface 2 Notes on using the operation manual 3 General safety information 4 Shipping and storage 5 Disposal B Basic information ............9 1 Laws, regulations, standards 2 Bathing water parameters 3 Process description 4 Function...
Page 4
Filter system GENO-mat F 500/600/610 three-phase current/AC EC declaration of conformity We hereby declare that the system specified below complies with the basic health and safety requirements of the applicable EU directives on the basis of the design and construction as well as the model that we have put onto the market.
Filter system GENO-mat F 500/600/610 A; three-phase current/AC General information 1 | Preface Thank you for opting for a Grünbeck product. Backed by decades of experience in the area of water treatment, we provide solutions for all kind of processes. Drinking water is classified as food and requires particular care.
Filter system GENO-mat F 500/600/610 three-phase current/AC 2 | Notes on using the operation manual This operation manual is intended for operators of our systems. It is divided into several chapters (a letter is assigned to each of them) that are listed in the “Table of contents” on page 2 in alphabetical order.
Page 7
Filter system GENO-mat F 500/600/610 A; three-phase current/AC 3.2 Operating Only allow persons who have read and understood this operation personnel manual to work with the system. Strictly observe the safety guidelines. 3.3 Designated use The system may only be used for the purpose outlined in the product description (chapter C).
Filter system GENO-mat F 500/600/610 three-phase current/AC 4 | Shipping and storage Caution! The system may be damaged by frost or high temperatures. In order to avoid damage of this kind: Protect from frost during transportation and storage! Do not install or store the system next to objects which radiate a lot of heat.
Filter system GENO-mat F 500/600/610 A; three-phase current/AC Basic information 1 | Laws, regulations, standards DIN-EN 16713 describes the treatment of swimming and bathing water in private swimming pools. The requirements of DIN-EN 16713 must be complied with in order to ensure good water quality and thus protect heath.
Page 10
Filter system GENO-mat F 500/600/610 three-phase current/AC Effective chlorine constituents effective acid alkaline pH value Fig. B-1: Chlorine effectiveness 2.2 Chlorine process Because of its high effectiveness, chlorine is probably the most widely used disinfection product. Total chlorine is made up of the free and bound chlorine.
Filter system GENO-mat F 500/600/610 A; three-phase current/AC Note: We recommend installing a water softener if the water hardness is > 14 °dH, in order to have a sufficient buffer effect, the hardness should not fall below 7 °dH. 3 | Process description GENO-mat F 500/600/610 A filter systems are configured as multi- layer filters and are used for filtering and heating pool water in private swimming pools with a pool volume up to approx.
Page 12
Filter system GENO-mat F 500/600/610 three-phase current/AC 4.2 Backwashing The filter material retains the dirt from the pool water, meaning that the flow resistance rises as a result of the accumulated dirt. This means the value shown on the pressure gauge increases while the flow rate decreases.
Grünbeck. Please add the necessary information to the table below to have it readily available whenever necessary. GENO-mat F 500 A filter system Automating current pump (AC) Three-phase pump (3P) Order number: 240 470...
Page 14
Measuring water sampling To drain Mounting plate To pool Automatic multi-way valve Circulation pump Control unit GENO-BW-tronic Filter tank Type designation plate Automatic actuator Fig. C-1: Components of GENO-mat F 500 A filter systems Order no. 240 962-inter_105 Author: fsei-mrie G:\BA-240962-INTER_105_F-500-600-610-A.DOCX...
Filter system GENO-mat F 500/600/610 A; three-phase current/AC 2.2 GENO-mat F 600/610 A, 3P/AC Mounting plate Control unit GENO-BW-tronic To pool Filter tank Automatic actuator Flexible hose Inspection opening To the drain Circulation pump (only F 610) Type designation plate Automatic multi-way valve From pool Deaeration device...
Filter system GENO-mat F 500/600/610 three-phase current/AC 3 | Technical specifications GENO-mat F 500/600/610 A filter systems are suitable for private swimming pools with a pool volume of up to approx. 35 m³, 70 m³ or 100 m³, and are supplied with an automatic multi-way valve. The external and internal PVC piping is configured with DN 40 or DN 50.
Page 17
Filter system GENO-mat F 500/600/610 A; three-phase current/AC Fig. C-3: Dimensional drawing of GENO-mat F 500 A filter system Fig. C-4: Installation: GENO-mat F 600/610 A filter system Order no. 240 962-inter_105 Author: fsei-mrie G:\BA-240962-INTER_105_F-500-600-610-A.DOCX...
Page 18
Filter system GENO-mat F 500/600/610 three-phase current/AC Technical specifications / Filter system GENO-mat F Dimensions 500 A; 500 A; 600 A; 600 A; 610 A; 610 A; Connection data Nominal connection diameter for R 2“ / DN 40 R 2" / DN 50 bathing water Nominal diameter of drain DN 100...
Filter system GENO-mat F 500/600/610 A; three-phase current/AC 4 | Intended use Filter systems of the GENO-mat F series are designed for filtering pool water in private swimming pools. The circulation pump pumps the pool water out of the raw water tank or via the skimmer to the filter system in which dirt particles are filtered out.
Filter system GENO-mat F 500/600/610 three-phase current/AC 6 | Scope of supply 6.1 Standard equipment • Complete filter system assembled, ready to connect, piping. • Operation manual. 6.2 Accessories Note: It is possible to retrofit existing filter systems with accessories. Please contact the representative responsible for your region and or Grünbeck's head office for further information.
Page 21
Filter system GENO-mat F 500/600/610 A; three-phase current/AC (B+C) Filter layer 37.5 kg (grain size 0.4 to 0.8 mm) (D+E) Freeboard (no filter material) AFM filter filling F 500 (glass granulate) 240 180 (A) Support layer 21 kg (grain size 1.0 to 2.0 mm) (B+C) Filter layer 32 kg (grain size 0.5 to 1.0 mm) (D+E) Freeboard (no filter material) Order no.
Page 22
Filter system GENO-mat F 500/600/610 three-phase current/AC Fig. C-6: Filling diagram for GENO-mat F 600 A Quartz sand filter filling F 600 200 560 (A) Support layer 50 kg (grain size 3.0 to 5.6 mm) (B) Filter layer 75 kg (grain size 1.0 to 2.2 mm) (C) Filter layer 75 kg (grain size 0.4 to 0.8 mm) (D) Freeboard (no filter material) Hydro-anthracite filter filling F 600...
Page 23
Filter system GENO-mat F 500/600/610 A; three-phase current/AC Quartz sand filter filling F 610 242 185 (A) Support layer 50 kg (grain size 3.0 to 5.6 mm) (B) Filter layer 75 kg (grain size 1.0 to 2.2 mm) (C) Filter layer 200 kg (grain size 0.4 to 0.8 mm) (D) Freeboard (no filter material) Hydro-anthracite filter filling F 610 242 190...
Filter system GENO-mat F 500/600/610 three-phase current/AC Installation 1 | General installation information The installation location must offer sufficient size and a foundation of adequate size and load carrying capacity must be provided. The technical room must have ventilation and a drainage connection, in addition the technical room must be free from frost.
Filter system GENO-mat F 500/600/610 A; three-phase current/AC 3 | Hydraulic installation Measuring and control system GENO-CPR-tronic 02 Shut-off valves provided by the client family Heating return Backwash line (Drain) GENO-WT-K compact heat exchanger Floor drain Heating flow including heating pump Measuring water sampling GENO-Schlauflex pH dosing system Measuring water return...
Page 26
Filter system GENO-mat F 500/600/610 three-phase current/AC The filter system is not allowed to be used as a fixed point for pipelines under any circumstances. The suction line diameter should be at least equal to the diameter of the suction pipe and must withstand the resulting negative pressure, i.e.
GENO-mat F 500/600/610 A; three-phase current/AC 4 | Filter fills 4.1 GENO-mat F 500 A filter system Note: Remove automatic multi-way valve, check filter nozzles are undamaged and before filling the filter, seal the riser pipe with the supplied filling and centring aid made of cardboard. Fill the filter container up to approx.
Page 28
Filter system GENO-mat F 500/600/610 three-phase current/AC 4.2 GENO-mat F 600 A filter system Note: Remove the black container lid, check the filter nozzles are undamaged and seal the upper funnel before filling the filter (e.g. study plastic bag). Fill the filter container up to approx. 1/3 with water, which has the effect of distributing the filter material more evenly and protecting the filter nozzles at the bottom.
Page 29
Filter system GENO-mat F 500/600/610 A; three-phase current/AC Note: Remove the bag from the upper funnel, clean the sealing surface and grease the O-ring. Make sure that the container lid is tightened evenly, diagonally across, after filling. 4.3 GENO-mat F 610 A filter system Note: Remove the black container lid, check the filter nozzles are undamaged and seal the upper funnel before filling the filter (e.g.
Filter system GENO-mat F 500/600/610 three-phase current/AC 5 | Electrical installation The electrical installation is only allowed to be carried out by an authorised electrician in accordance with the regulations of the electrical utility and the applicable VDE regulations. The client must provide an AC/DC sensitive ground fault circuit interrupter (trip current 30 mA).
Page 31
Filter system GENO-mat F 500/600/610 A; three-phase current/AC 5.1 Motherboard connection diagram (GENO-BW-tronic) Netzzuleitung 230 V / 50 Hz oder 400 V / 50 Hz Filterpumpe Reservierte Klemmen Netzausgang 1 F1 T10A Netzausgang 2 F3 T10A F4 T0,5A Heizungs-Umwälzpumpe Elektronik Magnetventil Frischwasser Motorventil Anforderung Heizung...
Page 32
Filter system GENO-mat F 500/600/610 three-phase current/AC Fü r Vernetzung: Jumper gesteckt, wenn BW-tronic ein Endgerät ist 75 76 77 Fü r Vernetzung: Jumper offen, wenn BW-tronic kein Endgerät ist B GND J1 J2 Fig. D-4: Connection diagram of the serial interface on the display board Wechselstrompumpe 230 V 8x PE Einspeisung 230 V / 50 Hz...
Page 33
Filter system GENO-mat F 500/600/610 A; three-phase current/AC Electrical connection Function Note Mains cable L1 Client's fuse 16 A slow-blow. In AC pumps with current consumption > 7 A, jumper Mains cable L2 terminals 1 and 2 together. Mains cable L3 Mains cable / filter pump N Mains cable PE Reserved...
Page 34
Filter system GENO-mat F 500/600/610 three-phase current/AC Function Note Motorised valve L Electrical power supply 230 V~ for a motorised valve. open The output can be used either for channel cleaning or in Motorised valve L closed small raw water storage tanks for backwashing, see Motorised valve N "Configuration"...
Page 35
Filter system GENO-mat F 500/600/610 A; three-phase current/AC Function Note The input signals of terminals 38 – 63 are designed for connecting voltage-free contacts. The encoder voltage 24 VDC is at the terminals identified with "+". Thermal protection filter Thermal protection integrated into the filter pump (NC contact) pump + (FBS ...
Page 36
Filter system GENO-mat F 500/600/610 three-phase current/AC Function Note Level "b" Level a: Overshoot: Switching on the filter pump outside Raw water tank the filter running times in automatic mode. Level switch Level b: Undershoot: Switching off the filter pump. Raw water tank + Level "a"...
Filter system GENO-mat F 500/600/610 A; three-phase current/AC Start-up The work described below may only be performed by trained experts. It is recommended that the device is started up by the Grünbeck technical service / an authorised specialist company. 1 | First fill of the pool In reinforced concrete pools, the leak test to demonstrate water leak- tightness should already have been undertaken with chlorinated water by a 14-day test filling.
Filter system GENO-mat F 500/600/610 three-phase current/AC 2 | Preparing the filter system • Carry out a visual check and leak test before commissioning, i.e. check all screw connections, valves and pipe connections. • The pool must be filled with water. •...
Filter system GENO-mat F 500/600/610 A; three-phase current/AC 3 | Taking the filter system into operation Note: We recommend storing the operation manual close to the system. This can be placed on the grey cover after commissioning, for example. • Set the output filter pressure (see pressure gauge on the filter container) during filter operation during commissioning using a ball valve on the pressure side to approx.
Filter system GENO-mat F 500/600/610 three-phase current/AC Operation 1 | Introduction The GENO-mat F 500/600/610 A filter system is a fully automatic system which is responsible for filtering the pool water for several hours a day depending on the pool type and pool use. Dirt particles collect in the filter during filtration and the filter pressure increases.
Page 41
Filter system GENO-mat F 500/600/610 A; three-phase current/AC Emptying The filter pump switches off for approx. 1 minute. The automatic actuator turns the valve disc of the automatic multi-way valve to the drainage position. The filter pump switches on and pumps the content of the pool to the drain connection until the operating mode is switched over.
Page 42
Filter system GENO-mat F 500/600/610 three-phase current/AC Switch back one menu level or Switch back from the main menu to the basic display or Discard a changed value and keep the old value Call up a submenu or a function or Accept a changed value Press >...
Page 43
Filter system GENO-mat F 500/600/610 A; three-phase current/AC Operation: In menus that are protected against unauthorised access, it is first necessary to enter the required code (in the "Operation" or Code: 0000 "Functions" menu only if this has been programmed by the owner / user): If no key is pressed, all menus revert to the basic display automatically after 10 minutes.
Page 44
Filter system GENO-mat F 500/600/610 three-phase current/AC 2.4 Structure of the main menu MAIN MENU: In the "Operation" menu, the owner / user of the system can adapt Operation the functions to his / her individual requirements. Access to this Configuration menu is not protected by a code request as standard.
Page 45
Filter system GENO-mat F 500/600/610 A; three-phase current/AC According to the programme times (factory setting – can be BACKWASH TIMES: changed according to individual requirements), rinsing of the filter Monday 00:00 Tuesday 00:00 system takes place if automatic mode is active. Wednesday 00:00 One automatic backwash can be programmed per day;...
Page 46
Filter system GENO-mat F 500/600/610 three-phase current/AC Note: However, it should be noted that reducing the temperature of the bathing water may also require a temperature reduction of the air conditioning system (air temperature should be approx. 2 °C warmer than the bathing water). If the "winter temperature"...
Page 47
Filter system GENO-mat F 500/600/610 A; three-phase current/AC Configuration (code 0290) Filter system 26 Standard types + freely editable attachment Pump manufacturer Filter pump 1~/3~ Rated current Delay time Thermal contact Automatic actuator (*) Only in systems with Step times automatic actuator Duration of backwash Rinsing duration...
Filter system GENO-mat F 500/600/610 three-phase current/AC Caution! The setting values of these parameters should only be changed if you are certain about what you are doing! If in doubt, please contact Grünbeck's technical customer service / authorised service company responsible for your area. 2.7 Overview of parameters in the "Configuration"...
Page 49
Filter system GENO-mat F 500/600/610 A; three-phase current/AC Menu item Factory setting Setting range Differential pressure response 2.0 minutes 0.0 ... 10.0 minutes delay Differential pressure 10.0 hours 0.1 ... 99.9 hours interlocking Temperature comparison --.- °C 10.0 ... 40.0 °C Current output 0 –...
Page 50
2.8 Explanation of parameters in the "Configuration" menu: In GENO-mat F filter systems, the appropriate data record is FILTER SYSTEM: programmed at the factory, meaning that the parameters are GENO-mat F 500 A, AC also set automatically. GENO-mat F 500 A, 3P GENO-mat F 500 HK, AC...
Page 51
Filter system GENO-mat F 500/600/610 A; three-phase current/AC Table F-2.9: Predefined data records Electrical Nominal Heating unit + Tempera- Automatic Data record Filter pump power pump heating / ture actuator circulation supply flow sensor pump F 500 HK, AC 230 V/50 Hz GENO-Top 8, AC 3.2 A F 500 HK, 3P...
Page 52
Filter system GENO-mat F 500/600/610 three-phase current/AC The parameters of the Filter pump menu are automatically FILTER PUMP: preconfigured by selecting one of the 26 standard filter systems. 1~ alternating current Rated current 0.0 A The following selections must be made in all other cases or if Delay 3 sec using a different filter pump:...
Page 53
Filter system GENO-mat F 500/600/610 A; three-phase current/AC The "Temperature sensor available" parameter is preconfigured TEMPERATURE SENSOR automatically by selecting one of the 26 standard filter systems. If available: there is no temperature sensor, the bathing water temperature is not shown in the basic display either. If the signal from a temperature limiter installed by the client is MAX:TEMPERATURBEGR.: MAX.
Page 54
Filter system GENO-mat F 500/600/610 three-phase current/AC so as to allow the required backwash water to be taken directly from the pool. Theoretically, two 2-way ball valves actuated in opposite directions can be used, although additional circuitry would be required for this! Each contact of the level control can be individually defined as an Waste water lift.
Page 55
Filter system GENO-mat F 500/600/610 A; three-phase current/AC Setting values for Address Baud rate connection of ... GENO- BW-Tip-control 4800 Touchpanel, GENO- 19200 SERIAL INTERFACE PARAMETER Address: CPR-tronic 02 family Baud rate: 4800 Printer 4800 Analog setting value of the PC interface A flow monitor provided by the client causes the filter pump to FLOW MONITOR: switch off if the flow monitor does not report any through-flow after...
Page 56
Filter system GENO-mat F 500/600/610 three-phase current/AC FLOW MONITOR PARAM.: "Parameters" contains the switch contact type and the Contact: NC Contact aforementioned delay time. Response delay 1 min The flow monitor is always interrogated when the filter pump is running, except during backwashing. In total, there are up to 3 alarm inputs available for system ALARM inputs: components on the input side.
Page 57
Filter system GENO-mat F 500/600/610 A; three-phase current/AC In automatic mode, the "Request heating" and "Operating Del. Enable signal message to measuring and control system" signals can be output min. for shorter than during the programmed filter run times: Later at the start of the filter run time, earlier at the end of the filter run time.
Page 58
Filter system GENO-mat F 500/600/610 three-phase current/AC 2.10 Alarm messages If one or more alarms are present, the display changes over and shows an alarm message of the error that occurred first instead of the basic display. If more than one alarm is active, it is possible to use the▲...
Page 59
Filter system GENO-mat F 500/600/610 A; three-phase current/AC The waste water lifting system can no longer pump the water ALARM: adequately out of the pump sump; the control unit goes to goes to OFF operating mode. Max.level lifting system Please check the delivery rate of the waste water lifting system. If it is working correctly, notify your technical customer service / authorised service company so that they can extend the waiting time for resetting the level switch signal if necessary.
Page 60
Filter system GENO-mat F 500/600/610 three-phase current/AC Internal electronics error. The current measurement of the filter pump ALARM: and the temperature measurement are significantly disrupted. Please notify your technical customer service / authorised service EEPROM1 def. ( comp) company so that they can replace the control unit. Here, the message text programmed for the particular alarm input ALARM: appears;...
Filter system GENO-mat F 500/600/610 A; three-phase current/AC Troubleshooting 1 | Introduction Operational errors cannot be completely ruled out even when the filter systems have been designed and produced with care and operated as intended. Table G-1 provides an overview of possible problems that may occur during the operation of the filter systems and indicates the causes and their elimination.
Filter system GENO-mat F 500/600/610 three-phase current/AC 2 | Fault overview Table G-1: Other errors This is what you This is the cause This is what to do observe No display on GENO- Defective motherboard or Notify the technical customer service / BW-tronic.
Page 63
Filter system GENO-mat F 500/600/610 A; three-phase current/AC Continuation Table G-1: Other errors This is what you This is the cause This is what to do observe Pump does not start up Incorrect voltage Compare the pump voltage (type designation plate) with mains voltage Fuse has tripped or is Find the cause and eliminate it, renew...
Filter system GENO-mat F 500/600/610 three-phase current/AC 3 | Failure of the motor (actuator) Note: All backwash times must be deactivated until the automatic actuator has been repaired (see chapter F-2.5). The position numbers (in brackets) relate to Fig. G-1. 1.
Filter system GENO-mat F 500/600/610 A; three-phase current/AC 4 | Defect of the switch circuit board (actuator) Note: All backwash times must be deactivated until the automatic actuator has been repaired (see chapter F-2.5). The position numbers (in brackets) relate to Fig. G-1. 1.
Filter system GENO-mat F 500/600/610 three-phase current/AC 5 | Removal of the automatic actuator Note: The item numbers (in brackets) relate to Fig. G-1. 1. Close shut-off valves provided by the client in the suction and pressure line. 2. Drain the filter system using the draining valve at the filter container, this process can be accelerated by lifting the valve disc (see point 2.1 to point 2.5).
Page 67
Filter system GENO-mat F 500/600/610 A; three-phase current/AC Fig. G-1: Exploded view of F 600 A automatic multi-way valve with automatic actuator Order no. 240 962-inter_105 Author: fsei-mrie G:\BA-240962-INTER_105_F-500-600-610-A.DOCX...
Page 68
Filter system GENO-mat F 500/600/610 three-phase current/AC Fig. G-2: Exploded view of F 500/610 A automatic multi-way valve with automatic actuator Order no. 240 962-inter_105 Author: fsei-mrie G:\BA-240962-INTER_105_F-500-600-610-A.DOCX...
Filter system GENO-mat F 500/600/610 A; three-phase current/AC Maintenance and care 1 | Basic information In order to guarantee the reliable function of the filter systems over a long period of time, some maintenance work has to be performed at regular intervals.
Filter system GENO-mat F 500/600/610 three-phase current/AC 2 | Inspection (functional check) You may perform the weekly inspections yourself: • Check the system components for leaks. • Perform at least one backwash (see chapter H-2.1). Note: We recommend changing 3 to 5 % of the pool water volume every week by adding freshwater.
Filter system GENO-mat F 500/600/610 A; three-phase current/AC 2.2 Hair and fibre strainer 1. Close the shut-off valves in the suction and pressure line. 2. Set the automatic multi-way valve to closed. 3. Unscrew the transparent cover on the circulation pump. 4.
Page 72
Filter system GENO-mat F 500/600/610 three-phase current/AC 5 | Operating log GENO-mat F 500 A GENO-mat F 600 A GENO-mat F 610 A Serial no.: ........Customer Name: ................. Address: ................................Start-up Installer: ..............Customer service technician: ........Company:..............
Page 73
Filter system GENO-mat F 500/600/610 A; three-phase current/AC Operating values Operating values Water temperature [°C] Water temperature [°C] pH value pH value Disinfectant content [mg/l] Disinfectant content [mg/l] Water hardness in the pool water [°dH] Water hardness in the pool water [°dH] Functional check / maintenance work Functional check / maintenance work System components checked for leaks...
Page 74
Filter system GENO-mat F 500/600/610 three-phase current/AC Operating values Operating values Water temperature [°C] Water temperature [°C] pH value pH value Disinfectant content [mg/l] Disinfectant content [mg/l] Water hardness in the pool water [°dH] Water hardness in the pool water [°dH] Functional check / maintenance work Functional check / maintenance work System components checked for leaks...
Page 75
Filter system GENO-mat F 500/600/610 A; three-phase current/AC Operating values Operating values Water temperature [°C] Water temperature [°C] pH value pH value Disinfectant content [mg/l] Disinfectant content [mg/l] Water hardness in the pool water [°dH] Water hardness in the pool water [°dH] Functional check / maintenance work Functional check / maintenance work System components checked for leaks...
Page 76
Filter system GENO-mat F 500/600/610 three-phase current/AC Operating values Operating values Water temperature [°C] Water temperature [°C] pH value pH value Disinfectant content [mg/l] Disinfectant content [mg/l] Water hardness in the pool water [°dH] Water hardness in the pool water [°dH] Functional check / maintenance work Functional check / maintenance work System components checked for leaks...
Page 77
Filter system GENO-mat F 500/600/610 A; three-phase current/AC Operating values Operating values Water temperature [°C] Water temperature [°C] pH value pH value Disinfectant content [mg/l] Disinfectant content [mg/l] Water hardness in the pool water [°dH] Water hardness in the pool water [°dH] Functional check / maintenance work Functional check / maintenance work System components checked for leaks...
Page 78
Filter system GENO-mat F 500/600/610 three-phase current/AC Operating values Operating values Water temperature [°C] Water temperature [°C] pH value pH value Disinfectant content [mg/l] Disinfectant content [mg/l] Water hardness in the pool water [°dH] Water hardness in the pool water [°dH] Functional check / maintenance work Functional check / maintenance work System components checked for leaks...