Hitachi RPI-8.0FSNQH Operation Installation Maintenance Manual page 22

Inverter-driven multi-split system heat pump air conditioners, indoor unit

Advertisement

5
(RSW1 & DSW6)
Setting
Position
Before shipment. DSW6 and RSW1 are set to "0".
Max.64 units are available to set when all the equipment
to be connected are corresponding to H-LINK
Max.16 units when the units corresponding/
non-corresponding to H-LINK are combined.
8.0
Capacity
Setting
Position
Ex.) Set at No.16 Unit
Set by inserting
DSW6
Slotted screwdriver
into the groove
Set No.1 Pin ON
RSW1
Set at "6"
10.0
Before shipment. DSW5 and RSW2 are set to "0".
Max.64 cycles are available to set when all the equipment
to be connected are corresponding to H-LINK.
Max.16 cycles when the units corresponding/
non-corresponding to H-LINK are combined.
15
Ex.) Set at No.5 Cycle
Set by inserting
Setting
Slotted screwdriver
Position
into the groove
DSW5
Set All Pins OFF
RSW2
Set at "5"