Solahart ET Series Owner's Manual

Solahart ET Series Owner's Manual

Inverter & battery

Advertisement

Owner's Guide
Goodwe Energy Storage Systems
ET and GEH Series Inverter &
Lynx Home F-Series Battery
Solahart PV and battery systems must be installed and serviced by a suitably qualified person.
Please leave this guide with the system owner.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ET Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Solahart ET Series

  • Page 1 Owner’s Guide Goodwe Energy Storage Systems ET and GEH Series Inverter & Lynx Home F-Series Battery Solahart PV and battery systems must be installed and serviced by a suitably qualified person. Please leave this guide with the system owner.
  • Page 2 Only Solahart parts and Solahart approved parts may be used. No substitute parts may be used without prior approval from Solahart Industries Pty Ltd. Only parts supplied by Solahart Industries Pty Ltd are covered by the Solahart warranty.
  • Page 3: Table Of Contents

    Important Safety Instructions ....................4 About Your Battery System ......................5 Operating Procedures ......................... 7 Inverter Status ..........................9 BATTERY Status ........................11 Electrical Safety ......................... 14 Maintenance ..........................14 Solahart PV System and/or battery Warranty - Australia Only ..........15...
  • Page 4: Important Safety Instructions

    ACTIONS TO UNDERTAKE IN THE EVENT OF AN EARTH FAULT ALARM OR TRIPPED AC/DC CIRCUIT BREAKER Limit access to all parts of the PV and Battery system. Contact Solahart Service on 1800 638 011 or your nearest Solahart dealer.
  • Page 5: About Your Battery System

    Note: It is optional to install an AC grid bypass switch on the Backup Circuit. Please confirm with the installer. • Smart Meter – measures net electrical power to and from the grid. For more information regarding the specific operation of a PV system, refer to the Solahart Owner’s Guide – PV systems.
  • Page 6 ABOUT YOUR BATTERY SYSTEM BASIC SYSTEM OPERATION The Solahart Complete and Retrofit systems increase energy independence by using the battery to store excess PV energy, which would otherwise be exported to the grid, so it can be used when required.
  • Page 7: Operating Procedures

    OPERATING PROCEDURES CHECK BEFORE POWER ON Check the following items before power on to avoid the battery system being damaged. POWER ON THE BATTERY SYSTEM Single Battery System Turn on the breaker between the inverter and the battery system. Turn on the air switch of the battery system.
  • Page 8 Supply Main Switch located in the switchboard must also be in the OFF position. Warning: PV Array DC Isolators do not de-energise the PV array and array cabling. Caution: If the Solahart Battery system is expected to be OFF for longer than one month, refer to the instructions supplied with the Battery.
  • Page 9: Inverter Status

    The GEH Series inverter status is indicated by several LEDs, please refer to the following table for details. Note: Refer to GoodWe GEH Series inverter user manuals for simple troubleshooting procudures. Note: If the Inverter LED Status indicates a FAULT, contact your nearest Solahart Dealer.
  • Page 10 The ET Series inverter status is indicated by several LEDs, please refer to the following table for details. Note: Refer to GoodWe ET Series inverter user manuals for simple troubleshooting procudures. Note: If the Inverter LED Status indicates a FAULT, contact your nearest Solahart Dealer.
  • Page 11: Battery Status

    BATTERY STATUS The battery status is indicated by several LEDs, please refer to the following table for details.
  • Page 13 Note: Refer to GoodWe Lynx F Series battery user manuals for simple troubleshooting procudures. Note: If the Battery LED Status indicates a FAULT, contact your nearest Solahart Dealer.
  • Page 14: Electrical Safety

    Note: Ensure that you have monitoring access to your Inverter & Battery System. If you do not, contact your nearest Solahart Dealer. For recommended maintenance of the PV system, refer to the Solahart Owner’s Guide for PV systems. RECOMMENDED MAINTENANCE SCHEDULE...
  • Page 15: Solahart Pv System And/Or Battery Warranty - Australia Only

    Limited Warranty. Solahart, in addition can provide preventative maintenance and advice on the operation of the PV System. You can contact Solahart on 1800 638 011 to arrange a service call or to find out details about this warranty.
  • Page 16 Solahart will pay the costs of a technical inspection and transport of defective or non-performing Modules to its nominated location. If the Module is found by Solahart not to be defective (including for any of the exclusions outlined in this warranty document), you agree to reimburse us for those costs on demand. All dismantling and reinstallation costs are your sole responsibility.
  • Page 17 If Solahart determines that a reported defect in relation to a LG Chem Battery is eligible for coverage under this Limited Warranty, Solahart will, at its sole option: Repair the defective LG Chem Battery; Replace the LG Chem Battery; or Provide a Refund to be calculated in accordance with the formula below.
  • Page 18 SolarEdge Energy Bank. If the SolarEdge Energy Bank is not connected to the SolarEdge Monitoring Portal, these upgrades will not be able to be made and Solahart will not be able to honour these warranties for the SolarEdge Energy Bank.
  • Page 19 If your BYD Battery-Box System fails to comply with the above warranties during the relevant BYD Warranty Period, Solahart will repair or replace the non-conforming Product or parts at no charge (or provide a partial refund) on the following conditions: Whether to repair or replace the Product will be determined by Solahart in its sole discretion.
  • Page 20 Reimbursement. Warranty Terms If Solahart determines in its sole discretion that you do not have a valid warranty claim, Solahart may invoice you for any inspection and transportation costs of the returned Product. Given the evolution of the technology, a replacement unit or a new device available at the time of the claim may not be compatible with the installed system.
  • Page 21 This Limited Warranty covers the cost of labour work and materials to return the Product to working functionally and the transportation costs, including shipments, taxes, customs and duties, of replacements. If a Product is found not to be covered by this Limited Warranty, Solahart reserves the right to charge a handling fee.
  • Page 22 Warranty coverage for labour – PV System and LG Chem Battery In addition to the above coverage, Solahart provides you with five (5) years of coverage, from the date of installation, for all labour costs involved with inspection by Solahart, removal or installation of warranted parts or components by Solahart of your PV System.
  • Page 23 Ignoring safety warnings and instructions contained in all documents relevant to the applicable Product. If your claim relates to a failure to operate in accordance with the Solahart Owner’s Guide as a result of one of the factors listed above, Solahart may charge you at its standard rates for its time and materials related to your claim.
  • Page 24 Quick Start Guide; (b) exposure of the Product to movement or shaking following installation, or temperatures of more than 50°C and/or below -10°C; (c) failure to notify Solahart of the defect or deterioration within 30 days of becoming aware of the defect or deterioration; (d) modification or repair of the Product without Solahart’s approval;...
  • Page 25 Tesla Powerwall Battery, or opening of the external casing of your Tesla Powerwall Battery, that is performed by anyone other than Solahart or a Solahart certified installer; (d) failure to operate or maintain your Tesla Powerwall Battery in accordance with the Owner’s Manual provided by Tesla;...
  • Page 26 This does not apply to the extent Solahart is liable under applicable mandatory laws. If you require a call out and we find that the fault is not covered by Solahart's warranty, you are responsible for our standard call out charge. If you wish to have the relevant component repaired or replaced by Solahart that service will be at your cost.
  • Page 27 Solahart will arrange for the Product to be tested and assessed. Solahart will inform you whether this will occur on-site or whether the Product must be sent elsewhere for testing and assessment. If Solahart determines in its sole discretion that you have a valid warranty claim, Solahart will organise for the repair or replacement of the Product or any component in accordance with this warranty.
  • Page 28 Exhibit A LG CHEM CAPACITY RETENTION LEVELS References in this Exhibit to the “Product” are to a LG Chem Battery. The Product will retain at least 60% of Nominal Energy* when the Product is operated under normal use, consistent with the specification and the Installation Manual provided by LG Chem is followed until the earliest to occur of: 10 years after the date of the initial installation;...
  • Page 29 The remaining Usable Energy is the integral of discharge time, current and voltage. Test value list: Product Type End of discharge Constant charge Constant voltage(V) voltage(V) current(A) HVM 8.3 HVM 11.0 HVM 13.8 HVM 16.6 HVM 19.3 HVM 22.1 Website: www.solahart.com.au Email: solahart@solahart.com.au Revision Date: 2023 January 122293 A...