EV7 -S 10. TROUBLESHOOTING If the suggested remedy does not solve the problem, contact Assistance Service. 10.1 Malfunctions Problem Remedy Cause 9999999 The scale is Reduce the weight to a value overloaded below the maximum scale capacity. The terminal Poor battery Carry out a "battery charging"...
Page 3
EV7 -S 10.2 Error messages Only one code is displayed with the errors. To delete it, reset the terminal. Problem Cause Remedy -01- Scale connector Switch the terminal off and disconnected or make sure that the connector Converter failure broken is correctly connected.
Page 4
EV7 -S PC.ERR Communication Check the cable that connects error with the PC to the PC. Make sure that the PC is on and that the program has been installed correctly. Make sure that the port that communicates with the PC has been set up: access the Setup Menu by following pathway...
Page 6
SOC. COOP. BILANCIAI CAMPOGALLIANO A.R.L. 41011 Campogalliano (MO) Via Ferrari, 16 tel. +39 (0)59 893 611 - fax +39 (0)59 527 079 home page: http://www.coopbilanciai.it E-mail:cb@coopbilanciai.it servizio post-vendita after sales service service après-vente Kundendienstservice servicio post-venta serviço pós-venda tel. +39 (0)59 893 612 - fax +39 (0)59 527 294...
Need help?
Do you have a question about the EV7-S and is the answer not in the manual?