2. SAFETY INSTRUCTION

2.1 Notes on Operation
• Allow 4 minutes for the compressor
to restart cooling. If you turn the air
conditioner off and immediately restart
it, allow 4 minutes for the compressor
to restart cooling. There is an electronic
device in the unit that keeps the
compressor turned off for 4 minutes for
safety.
• In the event of a power failure during
use, allow 4 minutes before restarting
the unit. After power is reinstated,
restart the portable air conditioner.
If the power was off for less than four
minutes, be sure to wait at least four
minutes before restarting the unit.
If you restart the air conditioner within
four minutes, a protective device in the
unit may cause the compressor to shut
off. This protective device will prevent
cooling for about 5 minutes. Any
previous setting will be cancelled and
the unit will return to its initial setting.
• When you turn the unit off in cooling
mode, the compressor will shut off
immediately and the upper/under fan
motor will stop running after 5 seconds.
If changing from cooling to fan mode,
the compressor will shut off
immediately and the under fan motor
will stop running after 5 seconds.
If changing from cooling to heating
mode, the compressor will shut off
immediately and the under fan motor
will stop running after 30 seconds.
• Low temperature operation: Is your
unit freezing up? Freezing may occur
when the unit is set close to 18ºC in
low ambient temperature conditions,
especially at night. In these conditions,
a further temperature drop may cause the
unit to freeze. Setting the unit to a higher
temperature will prevent it from freezing.
• Dry mode decreases room temperature.
Warm air will be blown out from the
exhaust air outlet, but this is normal and
does not indicate a problem with the unit.
• This portable air conditioner blows the
warm air generated by the unit outside the
room via the exhaust hose while in cool
mode. In the mean time, the same amount
of air will enter the room from outside
through any openings of the room.
• Any person who is involved with working
on or breaking into a refrigerant circuit
should hold a current valid certificate
from an industry-accredited assessment
authority, which authorises their
competence to handle refrigerants
safely in accordance with an industry
recognised assessment specification.
• Servicing shall only be performed
as recommended by the equipment
manufacturer. Maintenance and repair
requiring the assistance of other skilled
personnel shall be carried out under the
supervision of the person competent in
the use of flammable refrigerants.
• The working temperature range of the
portable air conditioner is 16-35ºC
(60-95ºF) under cooling mode; 5-27ºC
(41-80ºF) under heating mode.
• WiFi Working frequency and maximum
output power: 2412-2472 MHz, 15.72dBm
To prevent injury to the user or other
people and property damage, the
following instructions must be followed.
Incorrect operation due to ignoring
instructions may cause harm or damage.
The seriousness is classified by the
following indications:
WARNING!
This symbol indicates the possibility
of death or serious injury.
CAUTION!
This symbol indicates the possibility
of injury or damage to property.
Meanings of symbols used in this manual
are shown below:
This symbol indicates never to
do this.
This symbol indicates always
do this.