  ■ PRODUCT SPECIFICATION
• Operating ambient temperature: -10 to 55 °C
• Operating ambient humidity: 35 to 85 %
• Storage temperature: -25 to 65 °C
• Weight: Approx. 85 g (Includes mounting bracket.)
• Installation category: II
• Pollution degree: 2
• Altitude: 2000 m max.
  ■ ACCESSORY
• Mounting bracket ........................................... 1 pce.
• Knurled screw ................................................ 1 pce.
All manuals and user guides at all-guides.com
  ■ DIMENSIONS
48
6
36
45
  ■ INDICATION
• When temperature is below the thermometer's
measurement range, '---' is displayed.
• When temperature is above the thermometer's
measurement range, 'fff' is displayed.
• When thermistor has broken, '---' flashes.
• When thermistor has short-circuited, 'fff' flashes.
  ■ PRECAUTIONS
• The thermistor and thermometer are adjusted as a
set. Do not alter.
• Do not apply mechanical force to the tip of the
thermistor.
• Do not pull or push the thermistor with excessive
force for the thermistor is connected to internal part
of the thermistor.
• If the thermistor breaks, or if the thermistor is short-
circuited, the entire thermistor must be readjusted.
Contact your OMRON representative.
• No user serviceable parts.
• Return to your OMRON representative for all repairs.
31
25
33
  ■ MOUNTING AND PANEL CUTOUT
Mounting
Panel cutout
6
45.2
+ 0.5
– 0
32.2
● Do not mount the thermometer where it
will be subject to:
• Mechanical vibration or impact.
• Dust or corrosive gases.
• High humidity or splashing oil or water.
• High-frequency noise such as that produced by
welders or other equipment.
● To clean the case use a cloth moistened
with a neutral detergent or alcohol.
Do not use organic solvents such as
thinner or benzene, or highly alkaline or
acidic solutions as they may damage the
surface.
Precautions in Using the Product
When the product is used under the circumstances or
environment below, ensure adherence to limitations of the
ratings and functions. Also take countermeasures for
safety precautions such as fail-safe installations.
(1) Use under circumstances or environment which are not
described in the instruction manual.
(2) Use for nuclear power control, railway, aircraft, vehicle,
incinerator, medical equipment, entertainment equipment,
safety device, etc.
(3) Use for applications where death or serious property
damage is possible and extensive safety precautions are
required.
33.2
+ 0.5
– 0

Advertisement

loading

Summary of Contents for Omron E5LC

  • Page 1 (3) Use for applications where death or serious property • Mounting bracket ........... 1 pce. • No user serviceable parts. damage is possible and extensive safety precautions are • Knurled screw ..........1 pce. • Return to your OMRON representative for all repairs. required.
  • Page 2 All manuals and user guides at all-guides.com   ■外形寸法図   ■取付方法とパネルカット寸法 取付方法  パネルカッ ト寸法  45.2 + 0.5 – 0 32.2 E5LC 形   33.2 + 0.5 デジタル サーモ – 0 取扱説明書 ●次のような場所への取り付けは避けて下 オムロン製品をお買いあげいただきありがとうございます。 この製品を安全に正しく使用していただくために, お使い さい。 になる前にこの取扱説明書をお読みになり, 十分にご理解 してください。 ・機械的振動・衝撃の大きな場所。 お読みになった後も, いつも手元においてご使用ください。 ・塵埃の多い場所、腐蝕性ガスの発生する場所。...