Battery Disconnect Switch - Hitachi ZAXIS 135US-6 class Operator's Manual

Hydraulic excavator
Table of Contents

Advertisement

Battery Disconnect Switch

IMPORTANT:
 Do not turn the battery disconnect switch OFF while
engine is running or the key switch is in another
position than the OFF position. Failure to do so may
damage the electrical system.
 The DEF/AdBlue® Pump runs for a while after the
engine stops to return DEF/AdBlue® from piping
to the DEF/AdBlue® tank. Do not turn the battery
disconnect switch OFF when lamp (2) is lit. Doing so
may cause damage to parts related to the Urea SCR
system and/or system malfunction.
The battery disconnect switch differs from the engine start
key switch. When the battery disconnect switch is turned OFF,
the electrical system is cut off, so no electric current flows into
the entire circuit.
Before turning the battery disconnect switch OFF, be sure
to turn the key switch OFF and wait 5 minutes or more after
the engine stops. If the battery disconnect switch is turned
OFF within 5 minutes after the engine stops, it may result
in malfunction of the electrical system. When the battery
disconnect switch is turned from OFF to ON, the preset data
of the radio or clock may be initialized. Set the radio and clock
again.
OPERATOR'S STATION
1-158
Battery Disconnect Switch
ZX135US-6
Battery Disconnect Switch
ZX225USLC-6
Battery Disconnect Switch
ZX345USLC-6