Hitachi ZAXIS 135US-6 class Operator's Manual page 389

Hydraulic excavator
Table of Contents

Advertisement

ZX225USLC-6, 345USLC-6
IMPORTANT: Loose fan belt may result in insufficient
battery charging, engine overheating, as well as
premature belt wear. A belt that is too tight can
damage both water pump/alternator bearings as well
as the belt.
Inspect
Check fan belt tension by depressing the midpoint between
the fan pulley and the alternator pulley by your thumb
with a depressing force of approximately 98 N (10 kgf ).
Deflection must be within the value illustrated in the right.
Visually check the belt for wear. Replace it if necessary.
Adjust Drive Belt Tension
1. Loosen lock nut (1) at the top of alternator (3), and lock
nut (4) at the bottom of alternator (3).
2. Adjust belt tension by moving alternator (3) forward or
backward by using adjustment bolt (2).
3. Securely tighten lock nuts (1) and (4).
IMPORTANT: When a new belt is installed, be sure to re-
adjust the tension after operating the engine for 3 to 5
minutes at slow idle speed to be sure that the new belt
is seated correctly.
MAINTENANCE
Alternator Pulley
Alternator Pulley
7-97
5 to 6 mm
98 N (10 kgf)
ZX225USLC-6
5 to 6 mm
98 N (10 kgf)
ZX345USLC-6
1
4
Fan Pulley
Crank Pulley
M1GR-07-006
Fan Pulley
Crank Pulley
M1HM-07-001
2
3
M197-07-072

Advertisement

Table of Contents
loading

This manual is also suitable for:

Zaxis 225us-6 classZaxis 345us-6 classZaxis 135us-6Zaxis 225uslc-6Zaxis 345uslc-6

Table of Contents