LG GA-B409U QA Series Service Manual page 27

Table of Contents

Advertisement

• TEMPERATURE COMPENSATION OF FREEZER ROOM
Revi s ed resi s tance
470 Ω
Present resi s tance
NO T
470 Ω
COMPENS A T E
2k Ω
1 ° C ↓
3.3k Ω
2 ° C ↓
5.6k Ω
3 ° C ↓
8.2k Ω
4 ° C ↓
FREEZER
10k Ω
5 ° C ↓
ROOM
(R1)
12k Ω
6 ° C ↓
18k Ω
7 ° C ↓
33k Ω
8 ° C ↓
56k Ω
9 ° C ↓
180k Ω
10 ° C ↓
• This circuit is aimed to input the necessary temperature compen sation values into the MICOM in order to adjust the freezer tem p erature
which is different in each model.
All manuals and user guides at all-guides.com
2k Ω
3.3k Ω
5.6k Ω
1 ° C ↑
2 ° C ↑
3 ° C ↑
NO T
1 ° C ↑
2 ° C ↑
COMPENS A T E
NO T
1 ° C ↓
1 ° C ↑
COMPENS A T E
NO T
2 ° C ↓
1 ° C ↓
COMPENS A T E
3 ° C ↓
2 ° C ↓
1 ° C ↓
4 ° C ↓
3 ° C ↓
2 ° C ↓
5 ° C ↓
4 ° C ↓
3 ° C ↓
6 ° C ↓
5 ° C ↓
4 ° C ↓
7 ° C ↓
6 ° C ↓
5 ° C ↓
8 ° C ↓
7 ° C ↓
6 ° C ↓
9 ° C ↓
8 ° C ↓
7 ° C ↓
8.2k Ω
10k Ω
12k Ω
4 ° C ↑
5 ° C ↑
6 ° C ↑
3 ° C ↑
4 ° C ↑
5 ° C ↑
2 ° C ↑
3 ° C ↑
4 ° C ↑
1 ° C ↑
2 ° C ↑
3 ° C ↑
NO T
1 ° C ↑
2 ° C ↑
COMPENS A T E
NO T
1 ° C ↓
1 ° C ↑
COMPENS A T E
NO T
2 ° C ↓
1 ° C ↓
COMPENS A T E
3 ° C ↓
2 ° C ↓
1 ° C ↓
COMPENS A T E
4 ° C ↓
3 ° C ↓
2 ° C ↓
5 ° C ↓
4 ° C ↓
3 ° C ↓
6 ° C ↓
5 ° C ↓
4 ° C ↓
-
-
27
18k Ω
33k Ω
56k Ω
180k Ω
7 ° C ↑
8 ° C ↑
9 ° C ↑
10 ° C ↑
6 ° C ↑
7 ° C ↑
8 ° C ↑
5 ° C ↑
6 ° C ↑
7 ° C ↑
4 ° C ↑
5 ° C ↑
6 ° C ↑
3 ° C ↑
4 ° C ↑
5 ° C ↑
2 ° C ↑
3 ° C ↑
4 ° C ↑
1 ° C ↑
2 ° C ↑
3 ° C ↑
NO T
1 ° C ↑
2 ° C ↑
NO T
1 ° C ↓
1 ° C ↑
COMPENS A T E
NO T
2 ° C ↓
1 ° C ↓
COMPENS A T E
3 ° C ↓
2 ° C ↓
1 ° C ↓
COMPENS A T E
9 ° C ↑
8 ° C ↑
7 ° C ↑
6 ° C ↑
5 ° C ↑
4 ° C ↑
3 ° C ↑
2 ° C ↑
1 ° C ↑
NO T

Advertisement