Required Equipment

Multi-meter
Ampmeter
R-32 E.P.A. Approved Refrigerant Recovery System
Vacuum Pump rated for R-32 refrigerant (capable of 300 microns or less vacuum.)
Oxy/ Acetylene torch or similar equipment utilized for brazing.
Non-Sparking (Not Halide)Electronic Leak Detector rated for detecting R-32 refrigerant.
Digital refrigerant scale
High Pressure Gauge - (0 to 750 lbs.)
Low Pressure Gauge - (-30 to 200 lbs.)
Vacuum Gauge capable of 300 microns or less.
Facilities for flowing nitrogen through refrigeration tubing during all brazing processes.
EQUIPMENT MUST BE CAPABLE OF:
Recovering refrigerant to EPA required levels.
Evacuation from both the high side and low side of the system simultaneously.
Introducing refrigerant charge into high side of the system.
Accurately weighing the refrigerant charge introduced into the system.
37
R-32 SEALED SYSTEM REPAIR