Required Equipment
•
Multi-meter
•
Ampmeter
•
R-32 E.P.A. Approved Refrigerant Recovery System
•
Vacuum Pump rated for R-32 refrigerant (capable of 300 microns or less vacuum.)
•
Oxy/ Acetylene torch or similar equipment utilized for brazing.
•
Non-Sparking (Not Halide)Electronic Leak Detector rated for detecting R-32 refrigerant.
•
Digital refrigerant scale
•
High Pressure Gauge - (0 to 750 lbs.)
•
Low Pressure Gauge - (-30 to 200 lbs.)
•
Vacuum Gauge capable of 300 microns or less.
•
Facilities for flowing nitrogen through refrigeration tubing during all brazing processes.
EQUIPMENT MUST BE CAPABLE OF:
•
Recovering refrigerant to EPA required levels.
•
Evacuation from both the high side and low side of the system simultaneously.
•
Introducing refrigerant charge into high side of the system.
•
Accurately weighing the refrigerant charge introduced into the system.
37
R-32 SEALED SYSTEM REPAIR