Nothing is more important than air flow for the proper operation of a clothes
dryer. A dryer is a pump which draws make-up air from the out-of-doors, through
the heater, through the clothes and then forces the air through the exhaust duct
back to the out-of-doors. Just as in a fluid water pump, there must be a fluid air
flow to the inlet of the dryer, if there is to be the proper fluid air flow out of the
exhaust duct.
In summary, there must be the proper size out-of-doors inlet air opening (4-6
times the combined areas of the air outlet) and an exhaust duct, size and length of
which allows flow through the dryer with no more than 0.3 inches water column
(.75 mbar) static pressure in the exhaust duct.
In some instances, special fans are required to supply make-up air, and/or boost
exhaust fans are required for both regular and energy saving models.
FOR BEST DRYING:
1. Exhaust duct maximum length 14 feet (5 m) of straight duct and maximum
of two 90° bends.
2. Use 45° and 30° elbows wherever possible.
3. Exhaust each dryer separately.
4. Use 2 feet (0.6 m) of straight duct on dryer before installing an elbow on
energy-saver models only.
5. Do not install wire mesh or other restrictions in the exhaust duct.
6. Use clean-outs in the exhaust duct and clean periodically when needed.
Examine the exhaust system at least once every three months, and more
frequently if indicated.
7. Never exceed 0.3 inches water column (.75 mbar) static pressure in the
exhaust duct.
8. Inside surface of the duct must be smooth.
9. Recommend pop rivets for duct assembly.
FOR BEST DRYING:
1. Provide opening to the out-of-doors in accordance with the following:
For each dryer—
6 inches (153 mm) diameter exhaust requires a 1 square feet (0.1 m²)
opening for make-up air.
8 inches (204 mm) diameter exhaust requires a 2 square feet (0.2 m
opening for make-up air.
12 inches (305 mm) diameter exhaust requires a 4 square feet (0.4 m
opening for make-up air.
2. Use barometric shutters in the inlet air opening to control air when dryers
are not running.
Other Recommendations
To assure compliance, consult local building code requirements.
Troubleshooting
Hot dryer surfaces, scorched clothes, slow drying, lint accumulations, or air
switch malfunction are indicators of exhaust duct and/or make-up air problems.