4. CONTROL AND FUNCTIONS
1. Rotation number control of compressor...................................................04-1
1-1. Cooling operation ...........................................................................................................04-1
1-2. Heating operation ...........................................................................................................04-3
1-3. Dry operation ..................................................................................................................04-4
1-4. Rotation number of compressor at normal start-up ........................................................04-5
2. Auto changeover operation........................................................................04-8
3. Fan control.................................................................................................04-10
3-1. Indoor fan control..........................................................................................................04-10
3-2. Outdoor fan control.......................................................................................................04-14
4. Louver control ...........................................................................................04-17
4-1. Vertical airflow direction louver control .........................................................................04-17
4-2. Adjust the horizontal louver ..........................................................................................04-17
4-3. Swing operation............................................................................................................04-18
5. Timer operation control ............................................................................04-19
5-1. Wireless remote control ................................................................................................04-19
5-2. Wired remote control ....................................................................................................04-21
6. Defrost operation control .........................................................................04-24
6-1. Defrost operation in heating operation stopped ............................................................04-25
7. Various control ..........................................................................................04-26
7-1. Auto restart ...................................................................................................................04-26
7-2. MANUAL AUTO operation............................................................................................04-26
7-3. Forced cooling operation ..............................................................................................04-27
7-4. 10 °C HEAT operation ..................................................................................................04-27
7-5. ECONOMY operation ...................................................................................................04-27
7-6. POWERFUL operation .................................................................................................04-28
7-7. Fresh air control............................................................................................................04-28
7-8. Compressor preheating ................................................................................................04-28
7-9. External electrical heater control ..................................................................................04-29
7-10. Electronic expansion valve control .............................................................................04-29
7-11. Prevention to restart for 3 minutes (3 minutes st) .......................................................04-29
7-12. 4-way valve control.....................................................................................................04-29
7-13. Outdoor unit low noise operation ................................................................................04-30
8. Various protections...................................................................................04-31
8-1. Discharge gas temperature over-rise prevention control ..............................................04-31
8-2. Anti-freezing control (cooling and dry mode) ................................................................04-31
8-3. Current release control .................................................................................................04-32
8-4. Cooling pressure over-rise protection ...........................................................................04-32
8-5. Low outdoor temperature protection.............................................................................04-32
8-6. High temperature and high pressure release control ....................................................04-33