Operation - MULTIQUIP MAYCO LS600PWR Operation Manual

Concrete pump
Table of Contents

Advertisement

Starting Procedure
WARNING
DO NOT attempt to operate this concrete pump until
the Safety, General Information and Inspection sections
have been read and understood.
1. Locate the emergency stop switch (Figure 20) on
the digital control panel. Turn the emergency stop
switch clockwise and release (open). This will allow
the engine to start.
Figure 20. Emergency Stop Switch
NOTICE
If the emergency stop switch is in the closed position
(STOP), engine will not start. To start the engine, make
sure the emergency stop switch is in the OPEN position
(fully extended).
2. Place the cylinder stroke control switch in the
AUTOMATIC position (Figure 21).
AUTOMATIC
Figure 21. Cylinder Stroke Control Switch
(Automatic)
3. Place the pumping control switch in the CENTER
OFF position (Figure 22) for normal pumping operation.
LOCAL
Figure 22. Pumping Control Switch (OFF)
MAYCO LS600P CONCRETE PUMP • OPERATION MANUAL — REV. #1 (09/09/19) — PAGE 33
JOG
REMOTE
CENTER
OFF
4. Place the direction control switch to the FORWARD
position (Figure 23).
FORWARD
Figure 23. Direction Control Switch
(FORWARD)
5. To start the engine, insert the ignition key (Figure 24)
into the ignition switch and turn the key to the ON
position.
OFF
Figure 24. Ignition Switch
6. When the ignition key is in the ON position, the digital
readout screen (primary) will cycle through 3 displays
as shown in Figure 25.
LS 600 OFF
0000 ENG RPM
BATTERY 12.5 V
LOW OIL PSI
LS 600 OFF
0000 ENG RPM
BATTERY 12.5 V
LOW RPM FAULT
LS 600 OFF
0000 ENG RPM
BATTERY 12.5 V
END OF MESSAGE
Figure 25. Primary Screen (Ignition Key ON)
7. Turn the key to the START position and listen for the
engine to start. In warm weather let engine warm up
for 5 minutes. In cold weather, let engine warm up for
10 minutes.

OPERATION

REVERSE
ON
START
IGNITION
1
1
1