Cable Routing; Cable Routing For Sl Version - B&B Electronics Conel XR5i v2 User Manual

Industrial router
Table of Contents

Advertisement

5.6 Mechanical dimensions and mounting recommendations
Mounting recommendations:
possibility to be put on a work surface,
DIN rail with clips CKD2 (ELPAC clip SL for metal version) are included.
For the most of applications with a built-in router in a switch board it is possible to recognize
two kinds of environments:
no public and industry environment of low voltage with high interference,
public environment of low voltage without high interference.
For both of these environments it is possible to mount router to a switch board, the following
there is no need to have examination immunity or issues in connection with EMC according to
EN 60439-1 ed.2:00 + A1:04.
For compliance of EN 60439-1 ed.2:00 + A1:04 specification it is necessary to observe next
assembly of the router to the switch – board:
For every cables we recommend to bind the bunch according to the following picture, we
recommend for this use:
– Length of the bunch (combination of power supply and data cables) can be max-
imum 1,5 m. If the length of data cables exceeds 1,5 m or in the event of, the
cable leads towards the switch – board. We recommend installing over – voltage
protectors (surge suppressors).
– With data cables they mustn't carry cables with reticular tension
– All signals to sensors must be twisted pairs.
Figure 8: Cable routing
5. ROUTER DESIGN
Figure 9: Cable routing for SL version
8
230 V/50 Hz.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Conel xr5i v2fConel xr5i v2f sl

Table of Contents