Drainage Connection - Smeg K4610X Instruction Booklet

Table of Contents

Advertisement

EN
Instructions for the installer
6.2 Cable replacement
This should only be carried out by a qualified and authorised technician. The earth wire
should always be yellow-green.
Make sure that all electrical connections are tight before connecting the oven to the mains
power supply.
WARNING: incorrect connection could lead to the terminal board overheating, which
could cause it to melt or cause an electric shock.
Check for earth leakage between the phases and earth. Check for electrical continuity
between the external casing and the earth wire of the mains. We recommend using a
multimeter to perform these tasks.

7. DRAINAGE CONNECTION

7.1 Waste water
Water coming out from the drainage system of the appliance may reach high temperatures
(90°C). The hoses used for draining the water must be able to withstand such temperatures.
The water drainage pipe is located in the back of the appliance and should be connected
using a rigid or flexible pipe and conveyed to an open drain or a drain with a water trap; its
diameter must not be smaller than that of the appliance's drainage connection. It is
recommended that you install a suitable water trap between the appliance and the drain to
prevent vapours escaping from the hood and unpleasant odours entering from the drainage
system.
Avoid pinching in the hoses or elbow joints in rigid pipes along the entire drainage system.
Too ensure adequate flow, the pipe must have a minimum slope of 5% along its entire
length. Any pipes that are almost horizontal should not be longer than one metre.
The appliance must have its own connection to the drain. If there are other appliances or
equipment connected to a single pipe, make sure it is large enough allow proper drainage
and unobstructed flow.
Local regulations and standards must be followed.