Electrical Requirements - U.s.a. Only; Electrical Requirements - Canada Only - Jenn-Air RISE JDS1450ML Owner's Manual

Slide-in dual fuel range
Table of Contents

Advertisement

Available languages

Available languages

Electrical Requirements - U.S.A.
Only
If codes permit and a separate ground wire is used, it is
recommended that a qualified electrical installer determine that
the ground path and wire gauge are in accordance with local
codes.
Do not use an extension cord.
Be sure that the electrical connection and wire size are adequate
and in conformance with the National Electrical Code,
ANSI/ NFPA 70-latest edition and all local codes and ordinances.
A copy of the above code standards can be obtained from:
National Fire Protection Association
1 Batterymarch Park
Quincy, MA 02169-7471
WARNING: Improper connection of the equipment-grounding
conductor can result in a risk of electric shock. Check with a
qualified electrician or service technician if you are in doubt as to
whether the appliance is properly grounded. Do not modify the
power supply cord plug. If it will not fit the outlet, have a proper
outlet installed by a qualified electrician.
Electrical Connection
To properly install your range, you must determine the type of
electrical connection you will be using and follow the instructions
provided for it here.
� Range must be connected to the proper electrical voltage and
frequency as specified on the model/serial/rating plate. The
model/serial/rating plate is located behind the oven door on the
top right-hand side of the oven frame.
A. Model/serial/rating plate (located behind the oven door on the top
right-hand side of the oven frame)
Range Rating*
120/240 V
120/208 V
8.8-16.5 kW
7.8-12.5 kW
16.6-22.5 kW
12.6-18.5 kW
*The NEC calculated load is less than the total connected load
listed on the model/serial/rating plate.
**If connecting to a 50 A circuit, use a 50 A rated cord with kit. For
50 A rated cord kits, use kits that specify use with a nominal 1
(3.5 cm) diameter connection opening.
� A circuit breaker is recommended.
� The range can be connected directly to the circuit breaker box
� Allow at least 6 ft (1.8 m) of slack in the line so that the range
� A UL listed conduit connector must be provided at each end of
� Wire sizes and connections must conform with the rating of the
� The tech sheet is available online.
� This range is equipped with a CSA International Certified
� Do not use an extension cord.
Electrical Requirements - Canada
Only
A
If codes permit and a separate ground wire is used, it is
recommended that a qualified electrical installer determine that
the ground path is adequate and wire gauge are in accordance
with local codes.
Specified Rating of
Be sure that the electrical connection and wire size are adequate
Power Supply
and in conformance with CSA Standard C22.1, Canadian
Cord Kit and
Electrical Code, Part 1 - latest edition, and all local codes and
Circuit Protection
ordinances.
Ampere
A copy of the above code standards can be obtained from:
40 or 50**
50
� Check with a qualified electrical installer if you are not sure the
3
/
"
8
(or fused disconnect) through flexible or nonmetallic sheathed,
copper or aluminum cable. See the
"Electrical Connection -U.S.A. Only" section.
can be moved if servicing is ever necessary.
the power supply cable (at the range and at the junction box).
range.
Power Cord intended to be plugged into a standard 14-50R
wall receptacle. Be sure the wall receptacle is within reach of
range's final location.
WARNING
Electrical Shock Hazard
Electrically ground appliance.
Failure to do so could result in death, fire, or electrical
shock.
Canadian Standards Association
178 Rexdale Blvd.
Toronto, ON M9W 1R3 CANADA
range is properly grounded.
9

Advertisement

Table of Contents
loading

Table of Contents