Haier GE NF97UM Service Manual page 72

97% upflow/horizontal modulating variable speed gas furnace
Hide thumbs Also See for GE NF97UM:
Table of Contents

Advertisement

4
Safety
Check
Verify There
Is No Main Burner
Flame
Limit
NO
Switch
Closed?
YES
Rollout
Circuit
NO
Closed?
L
I
G
YES
H
T
O
Low
F
Pressure
NO
F
Switch
Open?
YES
Combustion Air Inducer ON at
Ignition at 70% rate speed
Low
Pressure Switch
NO
Closed Within 150
Seconds?
YES
Pre −Purge
15 Seconds
Ignitor ON
20 Seconds
Gas Valve
Energized
Ignition Trial Begins
Indoor Blower On
C
Ignitor ON
Delay Timer Started
A
L
L
F
Flame
O
Sensed Within
NO
R
4 seconds?
H
E
A
T
YES
Ignitor OFF
Wait For Ignition
Stabilization Delay
Set to
Low Firing Rate
Move to Mid Firing Rate
and High Firing Rate after
2nd and 3rd Stage Delays
(based on DI P Switch selections)
Figure 57. Ignition and Call for Low Fire with Single-Stage Thermostat
Indoor Blower OFF After
Heat OFF Delay
(Low Heat Speed)
De−Energize
Combustion Air
Error Code
Gas Valve
Inducer ON
(100%)
Combustion Air
Inducer ON
(100%)
De−Energize
Error Code
Gas Valve
Indoor Blower
ON
(70%)
High
Error Code Flashes
Pressure
NO
After 5 Seconds
Switch
Open?
Low Pressure
Switch Opens
YES
YES
Calibration
Pressure Switch
NO
Calibration
Successful?
Wait
5 minutes
Interpurge
(15 Seconds)
NO
Gas Valve
De−energized
5th
Unsuccessful
Trial?
Ignitor OFF
1
SOF T LOCKOUT IS RESE T AUTOMATICALLY AFTER ONE HOUR WITH A CALL FOR HEAT ACTIVE,
OR BY CYCLINGTHE CAL L FOR HEAT, OR BY CYCLING POWER TO THE CONTROL.
2
HARD LOCKOU T IS RESE T BY CYCLING POWER TO THE CONTROL.
Call For Heat Satisfied
3B
Page 72
YES
Indoor Blower
Limit
ON
Closes Within 3
Flashes
(100% Speed)
Minutes?
Rollout
Circuit
Flashes
Closes?
YES
NO
Combustion Air Inducer
OFF After Post-Purge
Indoor Blower OFF After
Error Code Flashes
After 5 Seconds
Heat OFF Delay
High Pressure
Hard Lockout:
Switch Opens
Error Code
Flashes
flashes
4
Soft Lockout:
Calibrations
YES
Error Code
Attempted?
Flashes
NO
Post − Purge
Combustion Air
YES
(20 Seconds)
Inducer OFF
NO
Indoor Blower OFF
After Heat OFF Delay
(High Heat Speed)
Soft Lockout:
Error Code
1
Flashes
2
Call
For
NO
Heat?
NO
YES
Call For
Heat
Ends?
YES
Indoor
Blower On?
YES
NO
Indoor Blower OFF
After Heat OFF Delay
1
Soft Lockout:
Error Code
1
Flashes
31-5000723 Rev. 0