Haier GE NF97UM Service Manual page 63

97% upflow/horizontal modulating variable speed gas furnace
Hide thumbs Also See for GE NF97UM:
Table of Contents

Advertisement

COMBUSTION
AIR INDUCER
CONNECTOR
DIAGNOSTIC
PUSH BUTTON
DIP SWITCHES
OUTDOOR AIR
TERMINALS
DISCHARGE AIR
TERMINALS
FACTORY TEST
HEADER PINS.
FACTORY USE ONLY.
E43 OUTDOOR
(NOT USED)
RS-BUS LINK (E3)
I+ = DATA HIGH CONNECTION
I - = DATA LOW CONNECTION
RS-BUS OUTDOOR (E43, not used)
R = 24VAC
I + = DATA HIGH CONNECTION
I - = DATA LOW CONNECTION
C = 24VAXC COMMON
RS-BUS INDOOR (E44, not used)
R = 24VAC
I + = DATA HIGH CONNECTION
I - = DATA LOW CONNECTION
C = 24VAXC COMMON
1/4" QUICK CONNECT TERMINALS
HUM = 120 VAC OUTPUT TO HUMIDIFIER
XMFR = 120 VAC OUTPUT TO TRANSFORMER
LI = 120 VAC INPUT TO CONTROL
CIRC = 120 VAC OUTPUT TO CIRCULATING BLOWER
EAC = 120 VAC OUTPUT TO ELECTRICAL AIR CLEANER
NEUTRALS = 120 VAC NEUTRAL
D i a g r a m
31-5000723 Rev. 0
FLAME
SENSE
SENSOR
SENSOR
E3
E43
E44 INDOOR
(NOT USED)
Figure 53. Integrated Control
7-SEGMENT
DIAGNOSTIC LED
E44
THERMOSTAT CONNECTIONS (E7)
DS = DEHUMIDIFICATION SIGNAL
W2 = HEAT DEMAND FROM 2ND STAGE T/STAT
W1 = HEAT DEMAND FROM 1ST STAGE T/STAT
R = CLASS 2 VOLTAGE TO THERMOSTAT
G = MANUAL FAN FROM THERMOSTAT
C = THERMOSTAT SIGNAL GROUNCONNECTED TO
TRANSFORMER GRD (TR) & CHASIS GROUND (GRD)
Y1 = THERMOSTAT 1ST STAGE COOL SIGNAL
Y2 = THERMOSTAT 2ND STAGE COOL SIGNAL
O = THERMOSTAT SIGNAL TO HEAT PUMP REVERSING
VALVE
H = 24V HUMIDIFIER OUTPUT
Page 63
NEUTRAL
TERMINALS
IGNITOR
CONNECTOR
LINE VOLTAGE
TERMINALS
HUM
EAC
INDOOR
BLOWER
CONNECTOR
W915 Y1 TO Y2
W951 R TO O
W914 R TO DS
W915
W951
W914