Download Print this page

Elkay LK4420BF1UDBFRKBLK Owner's Manual page 6

Bi-level tubular bottle filler fountain with pet fountain and sanitary freeze resistant triple valve control assembly

Advertisement

FOUNTAIN CONNECTIONS
INSTRUCTIONS FOR CONNECTING TUBES FROM VALVE TO FOUNTAIN(S)
Step 1 - Insert the 1/8" O.D. tube(s) (Labeled A, B & J) into the connector(s) (provided with fountain). Insert the 1/8" O.D. tube(s)
coming from the fountain(s) push button actuator(s) into the connector(s). Trim any excess length.
Step 2 - Secure the 1/8" O.D. tube(s) (Labeled C, D & K) to the waste line assembly. This line is a vent line and should be open
to the air.
Step 3 - Insert the 1/4" O.D. tube(s) (Labeled E, F & L) into the 1/4" union(s) (provided with valve assembly). Insert the
1/4" O.D. water lines coming from the fountain(s) into union(s). Trim any excess length.
Step 4 - Insert the 1/4" O.D. tube (Labeled G) into the air gap assembly.
Step 5 - Secure the 1/4" O.D. tube (Labeled H) to the waste line assembly. This line is a vent line and should be
open to the air.
LABEL L (Water Line)
(ON/OFF CONTROL LINE
FOR BUBBLER TWO)
LABEL C (VENT LINE)
LABEL H (VENT LINE)
LABEL D (VENT LINE)
LABEL K (VENT LINE)
1000003949
(Rev. A - 06/17)
4420DBBFFR_FTN _A
E
K
J
D
C
B
A
LABEL B
FOUNTAIN CONNECTIONS
WWW.RESTROOMDIRECT.COM
LK4420DBBFFR_FTN_A
F
G
L
PLUMBING CONDUIT
(BY INSTALLER)
FIG. 4
PAGE 6
704 • 937• 2673
TO VALVE
LABEL E (WATER LINE)
LABEL G (DRAIN LINE)
LABEL F (WATER LINE)
LABEL A
(ON/OFF CONTROL LINE
FOR BUBBLER ONE)
LABEL J
(ON/OFF CONTROL LINE
FOR BUBBLER THREE)
129 Oakpark Dr., Unit A, Mooresville, NC 28115

Advertisement

loading

This manual is also suitable for:

4420bf1ldbfr series4420bf1udbfr series