Advertisement

4. If unit is not level, tilt unit to access the front and rear level-
ing legs. For easier access to leveling legs, prop up unit with a
wooden block.
5. Loosen 7/8 in. locknut and adjust legs by screwing into or out
of unit base until the unit is level from side to side and front
to back (using a level). Unit should not rock.
NOTE: Leveling legs can also be adjusted from in-
side the unit using an adjustable wrench.
6. Tighten the locknuts securely against the unit base. If the
locknuts are not tight, unit will move out of position during
operation.
NOTE: DO NOT slide unit across floor if the leveling
legs have been extended. Legs and base could be-
come damaged.
7. Remove rubber feet from accessories bag and place on all
four leveling legs.
8. Verify that unit doesn't rock.
1
6
1. Leveling Leg
2. Washer Base
3. Level
4. Wood Block
5. Locknut
6. Rubber Foot
Figure 19

Wipe Out Inside of Wash Drum

Prior to first wash, use an all purpose cleaner or a detergent
and water solution and a damp cloth to remove shipping dust
from inside of the washer.
©
Published by permission of the copyright owner -
DO NOT COPY or TRANSMIT
2
5
4
FLW2335N_SVG

Connect the Washer to Electrical Power

This appliance is to be supplied through a residual current device
(RCD) having a rated residual operating current not exceeding 30
mA.
3
The appliance must not be supplied through an ex-
ternal switching device, such as a timer, or connec-
ted to a circuit that is regularly switched on and off
by a utility.

Electrical Requirements

230 Volt, 50 Hertz, 21 Amps
NOTE: This washer is factory-wired for a 230 Volt, Sin-
gle-Phase electrical supply.
NOTE: The wiring diagram is located in the control cab-
inet.
When connecting the washer to electrical power:
DO NOT overload circuits.
DO NOT use an extension cord.
DO NOT use an adapter.
DO NOT operate other appliances on the same circuit.
To reduce the risk of fire, electric shock, serious in-
jury or death, all wiring and protective earth/ground
connections MUST abide with local electrical codes.
It is the customer's responsibility to have the wiring,
fuses and circuit breakers installed by a qualified
electrician to make sure adequate electrical power is
available to the washer.