Converting From 230 Volt/Single-Phase To 400 Volt/3-Phase Wye - JLA 98 Installation & Operation Manual

Frontload washers
Table of Contents

Advertisement

Installation
Terminal Block Wired For 230 Volt Single-Phase As
Viewed Through Rear Access Panel
1
2
3
L 1
10
1. Black Wire
2. Black/White Wire
3. Black/Red Wire
4. White/Black Wire
5. White/Red Wire
6. White Wire
7. Green/Yellow Wire
8. Earth/Ground - Power Cord
9. Neutral
10. 230 Volt
Converting from 230 Volt/Single-Phase to 400
Volt/3-Phase WYE
To convert from 230 Volt, 2 wire plus earth, 21 Amp, Single-
Phase to 400 Volt, 9.8 Amp, 3-Phase WYE connection. Refer to
Figure 9 and Figure 11 :
1. Remove electrical access panel on rear of machine.
2. Remove plastic plug from hole in rear of machine.
3. Install strain relief, supplied with machine, in hole.
4. Put power cord through hole.
©
Published by permission of the copyright owner -
DO NOT COPY or TRANSMIT
4
7
6
5
N
9
FLW2030N_SVG1
Figure 9
8
1. Install power cord through this hole after removing plastic
plug. Use strain relief supplied in accessories bag.
5. On terminal block quick-disconnect terminals, remove black/
white wire from L1 and attach to terminal L2.
6. Move black/red wire from L1 to L3.
7. Place one 506113 Sticker, supplied with washer, near each of
the two serial plates. Mark correct voltage on sticker.
8. Place 511568 Label, supplied with washer, underneath termi-
nal block. Refer to Figure 11 .
9. Attach power cord wires as shown in Figure 11 .
10. Reinstall access panel.
NOTE: 1.5 mm
nection.
14
FLW2337N_SVG1
Figure 10
2
wire required for 3 phase, 4 wire con-
1
Part No. 805412R7

Advertisement