Installer Setting - Setting Address Of Central Control - LG ABQ48GM3A4 Installation Manual

Hide thumbs Also See for ABQ48GM3A4:
Table of Contents

Advertisement

Installer Setting - Setting Address of Central Control

It's the function to use for connecting central control.
Please refer to central controller manual for the details
FAN
SPEED
TEMP
- If you connect the indoor unit to the
central controller, you should set the
network address of the indoor unit so
that the central controller could
recognize it.
- The center-control address is composed
of the group number and the indoor-unit
number.
NOTE
The remote controller displays 'HL' if central controller has locked the remote controller .
* In the case when the lock is set up at the central controller, 'HL' will be indicated on the display
window of the wired remote controller and the indoor unit will not be controlled by the remote
controller.
1
2
OPER
MODE
3
4
OPTIONAL OPERATION
When pressing the
button simultaneously for more than 3
seconds, the system will be entered into the
installer setting mode.
- After entering into the installer setting mode,
select the central control address setting
code value by pressing the
* Setting address of central control code
value : 02
Set up the group number and indoor unit with
the temperature adjustment(▲,▼) buttons.
Group number
TEMP
Indoor unit number
For example, when setting as
[ Group number=2
Indoor number=3 ]
it will be displayed as shown in the left figure.
When pressing the
will be set up with the address value which
has been established at present.
When pressing the
button simultaneously for more than 3
seconds after the setting has been
completed, the setting mode will be released.
- If there isn't any button input for more than
25 seconds, the installer setting mode will
also be released.
21
OPER
button and
MODE
OPER
button.
MODE
button, the system
button and
OPER
MODE

Advertisement

Table of Contents
loading

Table of Contents