4.2. Wireless remote controlled start (where fitted).
4.2.1. With the ignition switch in the OFF position, and the machine in all other aspects ready
for operation (see usermanual).
4.2.2. The remote control has an approximate range of 25 metres in line of sight with no
obstructions. This distance will reduce as the battery power depletes.
4.2.3. Pull back the protection shroud (4) to reveal the ON – OFF control buttons (1&3)
4.2.4. To start the machine press button (3) twice each time the tell-tale LED (Blue) will light.
N.B. the first press arms system, second press starts machine.
4.2.5. The machine will crank 3 times until started, if there is a NO start then a pause of 3
seconds,
4.2.6. The machine will crank 5 times until started, if there is a NO start then a pause of 3
seconds,
4.2.7. The machine will crank for 7 times until started, if there is NO start the machines wireless
receiver will emit a 'beeping sound'. You will now have to turn the machine OFF and back
on to reset the wireless receiver.
4.2.8. The following are possible causes for a NO start,
4.2.8.1.
STOP/START lever in STOP position.
4.2.8.2.
Emergency STOP buttonactivated.
4.2.8.3.
Low or no fuel.
4.2.8.4.
Flat battery.
4.3. Checks whilst generator is running.
4.3.1. After each use make sure that there are no abnormal sounds or vibration.
4.3.2. Check that the engine is running smoothly normally.
4.3.3. Check that there is no excessive smoke from the exhaust after 10 minutes of
running, and the engine has reached working temperature
4.3.4. Check that there are no oil or fuel leaks.
If the engine has been running, the muffler will become very hot. Be
careful not to touch the muffler until it has had time to fully cool
down.
Never refuel the fuel tank whilst the engine is still running.