Digital lighting management ultrasonic ceiling mount occupancy sensor

Advertisement

Quick Links

THIS UNIT IS PRE-SET FOR PLUG N' GO™
OPERATION, ADJUSTMENT IS OPTIONAL.
For full operational details, adjustment and more
features of the product, see the DLM System Installation
Guide supplied with the LMRC-102 and also available at
www.wattstopper.com
INSTALLATION SHALL BE
IN ACCORDANCE WITH ALL
APPLICABLE REGULATIONS,
LOCAL AND NEC CODES.
Intended for Listed Class 2 DLM
Devices.
For Class 2 DLM devices -
To be connected to a Class 2
power source only.
SENSOR PLACEMENT (10' MAX. HEIGHT)
31.6'
9.63m
max.
COVERAGE PATTERN
The LMUC-100 provides a 360° coverage pattern.The
coverage shown represents maximum coverage for
walking motion at a mounting height of 8 to 10 feet.
CONNECTIVITY
The illustrations below show examples of free-topology wiring. The LMDC-100 communicates to all other Digital Lighting
Management devices connected to the low voltage DLM Local Network, regardless of their position on the DLM Local Network.
Corner Mount
Ceiling Mount
Sensor
Sensor
DLM Local Network
Low Voltage
LMRJ Cables
Switch
Switch
Daylight Sensor
For Class 2 Device Wiring Only –
Do Not Reclassify and Install as
Class 1, or Power and Lighting
Wiring.
Wire connections shall be rated
suitable for the wire size (lead
and building wiring) employed.
31.6'
9.63m
max.
Sensor
Line
Voltage
Line/Hot
Neutral
Black wire
White wire
Loads
1
LMRC
102
2
Room
Controller
Yellow wire
Red wire
to Load B (2)
to Load A (1)
J-Boxes
Voltage: .....................................................................................24VDC
Current Consumption: ...............................................................20mA
Power Supply: ................... Watt Stopper/Legrand Room Controllers
Connection to the DLM Local Network ........................ 2 RJ-45 ports
DLM Local Network Characteristics:
Provides low voltage power over Cat 5e cable (LMRJ).
Supports up to 24 communicating devices, including 4
LMRC-10x or LMPL-101 max per each DLM Local Network
Free topology up to 1,000ft of low voltage cable.
Environment .......................................................For Indoor Use Only
Operating Temperature ................. 32° to 131°F (0° to 55°C)
Storage Temperature ....................23° to 176°F (-5° to 80°C)
Relative Humidity ........................ 5 to 95% (non condensing)
Patent Pending
30'
9.14m
Sensor
50'
15.24m
To
Load
LMUC-100
Digital Lighting Management
Ultrasonic Ceiling Mount
Occupancy Sensor
Sensor
6'
Mount sensor at least 6' away
from strong air supply
Major Motion
Minor Motion
22.3 ft
31.6 ft
6.79m
9.63m
Room
Controller
J Box
Switch
Ceiling Mount
Occupancy
Sensor
Strong air
supply