Field
Tunnel Name
WAN Interface
Primary Remote End
Secondary Remote End (optional)
Connected Remote End
Connectivity check
Traffic timeout to start pings
No. of retries before unreachable
December 2021
Issue 1
Description
Select Create new GRE Tunnel or select an existing tunnel from the list.
The tunnel name is automatically assigned by the system.
Up to 4 GRE tunnels are supported.
Select a WAN interface from the list.
GRE tunnels can only be created on HSI-enabled WAN interfaces.
Enter an IP address or FQDN that is unique in the system.
If the primary remote endpoint is down or unreachable, the secondary remote endpoint
becomes active, if configured.
The secondary remote endpoint remains active until it becomes unreachable, in which
case the primary remote endpoint becomes active again. Revertive mode is not
supported.
If both endpoints are unreachable, the GRE tunnel is declared down.
This field displays the current data traffic path for the GRE tunnel.
This feature is automatically selected by the system.
Enter the traffic timeout in seconds (2 to 1024).
Enter the number of retries before the tunnel is declared down (0 to 100).