6
Secondary Device Functions (continued)
6.4.4
ISDU
Minimum, Maximum, Average and Moving
Average outputs are output in FLOAT32 format.
Before they are processed further and converted
from FLOAT32 to INT32 or UINT32, the output
signal must be checked to determine whether it
is larger than INT32_Max or UINT32_Max. If it is
larger, data type UINT64 or INT64 should be
used.
Name
Statistics Data
Configuration
Input Signal
Time Period Unit
Time Period Value
Moving Average
Window Unit
Moving Average
Window Value
Statistics Data
Output
Minimum
Maximum
Average
Moving Average
Number Of Samples
Status
Tab. 6-21: Basic statistics – ISDU
Statistics Data Configuration: Input Signal
All data types of process data objects can be used for
input configuration, with the exception of Boolean. The
respective Object IDs can be found in the respective
section on the function. Default value is 0, this corresponds
to "no object".
44
english
Index
Subindex
Access
0x0426
0
R/W
(1062)
1
R/W
2
R/W
3
R/W
4
R/W
5
R/W
0x0427
0
(1063)
1
2
3
4
5
6
Length
Data Type
8 bytes
2 bytes
UINT16(ENUM)
1 byte
UINT8(ENUM)
2 bytes
UINT16
1 byte
UINT8(ENUM)
2 bytes
UINT16
R
21 bytes
R
4 bytes
FLOAT32
R
4 bytes
FLOAT32
R
4 bytes
FLOAT32
R
4 bytes
FLOAT32
R
4 bytes
UINT32
R
1 byte
UINT8
Data Storage
Default
Yes
No
0
No
Seconds
No
1
No
Measure-
ment values
No
100
n/a
n/a
n/a
n/a
n/a
n/a
n/a