Power Port Upgrade Instructions for P300 and P600 Power Plants
Please read these instructions before attempting to install the new PS Audio Power Port AC
receptacles in your P300 or P600 Power Plant. These new receptacles replace the existing
hospital grade receptacles and are designed to improve the performance of your Power Plant.
Your kit contains the following:
Power Ports
New mounting hardware: 2 black screws (3 for P300) and two nuts for each Power Port
Instruction manual

Tools required:

One small and one medium Phillips screwdriver
Large heavy duty pair of wire-cutters or tin snips (pliers will also work)
P600 only – Allen wrench originally supplied for removing top cover

General Walk through

The replacement of the rear-mounted outlets is rather simple. Here are the basic steps you will
be taking:
1. Disconnect your Power Plant from its power supply.
2. Place unit in a well-lit workspace and obtain all necessary tools.
3. Remove the bottom cover of a P300, or the top cover of a P600.
4. Remove the existing hospital grade outlets and replace with a Power Port.
5. Replace the top or bottom cover.
6. You are done.
The procedure for replacing the hospital grade outlets with Power Ports, once inside the unit, is
very similar for each model. The differences per model are in gaining access to the inside of the
unit, and re-attaching the plugs back onto the rear panel.

Gaining access to inside the P300

Step One
Disconnect the Power Plant.
IMPORTANT! To correctly discharge the internal energy storage and prevent a potential shock
hazard, you must unplug the Power Plant while it is turned on and providing power for at least
one product. This will not damage the Power Plant or the connected device. However to ensure
that your equipment does not get damaged we recommend you use a simple load device such as
a table lamp for this step. (It will typically take less then 5 seconds for the unit to fully discharge.)
Once your Power Plant has cooled sufficiently to the touch, Place it in a well-lit place such as on
a table or open floor where you can have easy access and plenty of space to work on it. Make
sure you have all required tools available.
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the P-300 and is the answer not in the manual?

Questions and answers

Summary of Contents for PS Audio P-300

  • Page 1 Power Port Upgrade Instructions for P300 and P600 Power Plants Please read these instructions before attempting to install the new PS Audio Power Port AC receptacles in your P300 or P600 Power Plant. These new receptacles replace the existing hospital grade receptacles and are designed to improve the performance of your Power Plant.
  • Page 2 The board goes in only one way. The board components face the front panel of the P300. Failure to replace the board properly will damage the P300. If in doubt please call PS Audio. If your P300 is equipped with a fan kit, follow the two white wires attached to the bottom plate and remove the white plug from the motherboard.
  • Page 3 Step Two Remove the wires on one outlet at a time. There are four wires connecting the outlet: black, white and two green*. Remove the black and white wires, by loosening the side-mounted screws on the outlet. The wires will pull out easily. The green wires are removed by unscrewing the green Phillips screw.
  • Page 4 Step Four Replace the top cover. Congratulations, you are done. Your Power Plant is now equipped with the latest power delivery technology available!! PS Audio International, 3050 Broadway, Suite 201, Boulder Colorado, 80304 USA. 720-406-8946. WWW.PSAUDIO.COM Made in USA...

This manual is also suitable for:

P600

Table of Contents