Configuration Guide
Revision History .........................................................................................v
Restore Default Settings ............................................................................1
Exit Setup without Changes......................................................................1
Set Connection............................................................................................1
RF Auto Shutdown Duration....................................................................1
Transmit Buffer Setting ............................................................................1
Memory Mode Parameters .......................................................................2
List Setting..................................................................................................3
Buzzer Settings ...........................................................................................3
Reading Redundancy Setting....................................................................4
Scan Mode Setting .....................................................................................4
Auto-Sense Setting .....................................................................................4
Scanner Time-out Duration ......................................................................5
Negative Barcode Setting ..........................................................................5
Delay between Reread ...............................................................................5
Keyboard Wedge Parameters ...................................................................6
RS-232 Parameters ....................................................................................9
Bluetooth Serial Port Parameters...........................................................11
Bluetooth HID Parameters......................................................................12
Prefix / Postfix Settings............................................................................15
Character Substitution ............................................................................15
Code ID Selection.....................................................................................15
Code ID Setting ........................................................................................16
Length Code Setting (2 digits) ................................................................18
Select Readable Codes .............................................................................21
Code39 Parameters..................................................................................26
Italy Pharmacode Parameters ................................................................26
French Pharmacode Parameters ............................................................27
Industrial 25 Parameters.........................................................................27
Interleave 25 Parameters ........................................................................28
Matrix 25 Parameters..............................................................................30
Codabar Parameters................................................................................31
Plessey Parameters...................................................................................32
Telepen Parameters .................................................................................32
MSI Parameters .......................................................................................33
EAN128 Parameters ................................................................................34
EAN8 Parameters ....................................................................................35

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Xi3000BT and is the answer not in the manual?

Questions and answers

Summary of Contents for POS-X Xi3000BT

  • Page 1: Table Of Contents

    Memory Mode Parameters ...2 List Setting...3 Buzzer Settings ...3 Reading Redundancy Setting...4 Scan Mode Setting ...4 Auto-Sense Setting ...4 Scanner Time-out Duration ...5 Negative Barcode Setting ...5 Delay between Reread ...5 Keyboard Wedge Parameters ...6 RS-232 Parameters ...9 Bluetooth Serial Port Parameters...11 Bluetooth HID Parameters...12...
  • Page 2 UPCA Parameters...35 UPCE Parameters...36 EAN13 Parameters ...37 RSS Code ID Selection ...38 RSS14 Parameters ...38 RSS Limited Parameters...39 RSS Expanded Parameters ...39 Activate Editing Formats ...40 Editing Format Parameters ...41 Decimal Digits ...53 Hexadecimal Digits ...54 Key Type...55 Key Status...55 KBD Wedge Character Table...56 RS-232 Character Table...56...
  • Page 3: Revision History

    Revision History Version Release Date V 1.00 Oct. 31, 2005 First release. V 2.00 Dec.30, 2005 Supports Bluetooth HID. Firmware version: V4.10 V2.10 Jan.18, 2006 1. Updated: Bluetooth HID: The default setting of Capital Lock Setting is changed from Auto Detection to Capital Lock OFF.
  • Page 4: Restore Default Settings

    Restore Default Settings Exit Setup without Changes Set Connection Programming Instructions: (1) Read the label. (2) Read the Serial Number barcode on the bottom of the desired Xi3000 Base Station within 5 seconds to complete this setting. RF Auto Shutdown Duration Programming Instructions: (1) Read the label.
  • Page 5: List Setting

    List Setting Page1 Page 2 Page 3 Page 4 Page 5 Buzzer Settings < Buzzer Enable> • Buzzer Frequency 8 kHz 2 kHz Update Reading Redundancy Setting Page 6 Page 7 Scan Mode Setting Page 8 Page 9 Page 10 Auto-Sense Setting Buzzer Disable <...
  • Page 6: Scanner Time-Out Duration

    Scanner Time-out Duration Programming Instructions: (1) Read the label. (2) Program the desired time-out duration by reading Decimal Digits on page 52. (3) Read the “Validate” label (also on page 53) to complete this setting. Negative Barcode Setting Enable Delay between Reread...
  • Page 7 • Keyboard Alphabets Layout < Default Layout > QWERTZ • Keyboard Digits Layout < Default Layout > Upper Row • Keyboard Capital Lock Type < Default > Capital Lock • Capital Lock Setting Capital Lock ON < Capital Lock OFF > Auto Detection Update AZERTY...
  • Page 8: Rs-232 Parameters

    < 9600 > character delay by reading Decimal Digits on page 52. (3) Read the “Validate” label (also on page 52) to complete this setting. 2400 (single port only) < None > Scanner Ready Data Ready INV. Data Ready Enter Setup...
  • Page 9: Bluetooth Serial Port Parameters

    Bluetooth Serial Port Parameters • Activate Bluetooth Serial Port Interface • Device Name Broadcasting < Yes > • Authentication • PIN Code Programming Instructions: (1) Read the label. (2) Program the desired character string by reading Hexadecimal Digits on page 53. One character consists of 2 hexadecimal digits.
  • Page 10 • Authentication • PIN Code Programming Instructions: (1) Read the label. (2) Program the desired character string by reading Hexadecimal Digits on page 53. One character consists of 2 hexadecimal digits. (3) Read the “Validate” label (also on page 53) to complete this setting.
  • Page 11: Prefix / Postfix Settings

    • Digits Transmission < Alphanumeric Key > • Alt Composing Prefix / Postfix Settings Prefix Code * Character Substitution Set 1 * Set 3 * Programming Instructions: (1) Read the label. (2) Program the desired character string by reading Hexadecimal Digits on page 53. One character consists of 2 hexadecimal digits.
  • Page 12: Length Code Setting (2 Digits)

    Code 128 * Plessey * Programming Instructions: (1) Read the label. (2) Program the desired character string by reading Hexadecimal Digits on page 53. One character consists of 2 hexadecimal digits. (3) Read the “Validate” label (also on page 53) to complete this setting.
  • Page 13 • Matrix 25 Length Code Enable • Codabar Length Code Enable • UPCA Length Code Enable • UPCE Length Code Enable • EAN8 Length Code Enable • EAN13 Length Code Enable Update < Disable > < Disable > < Disable > <...
  • Page 14: Select Readable Codes

    Select Readable Codes • Code 39 < Enable > • Italy Pharmacode Enable • French Pharmacode Enable • Industrial 25 < Enable > • Interleave 25 < Enable > Update Disable < Disable > < Disable > Disable Disable • Matrix 25 Enable •...
  • Page 15 • Plessey Enable • Telepen Enable • UPCA < Enable No Addon > Disable No Addon Enable Addon2 < Disable Addon2 > Enable Addon5 < Disable Addon5 > Update < Disable > < Disable > • UPCE < Enable No Addon > Disable No Addon Enable Addon2 <...
  • Page 16: Code39 Parameters

    • EAN13 < Enable No Addon > Disable No Addon Enable Addon2 < Disable Addon2 > Enable Addon5 < Disable Addon5 > • RSS14 Enable • RSS Limited Enable • RSS Expanded Enable Update Code39 Parameters • Standard / Full ASCII Code39 •...
  • Page 17: French Pharmacode Parameters

    French Pharmacode Parameters • Checksum Transmission < Enable > Industrial 25 Parameters • Start / Stop Selection < Industrial 25 > Matrix 25 • Checksum Verification Enable • Checksum Transmission < Enable > Update Disable Interleave 25 Interleave 25 Parameters <...
  • Page 18: Matrix 25 Parameters

    • Checksum Verification Enable • Checksum Transmission < Enable > • Max / Min Code Length Qualification Select Max / Min Length Qualification Max Length * Programming Instructions: (1) Read the label. (2) Program the desired length by reading Decimal Digits on page 52. (3) Read the “Validate” label (also on page 53) to complete this setting.
  • Page 19: Codabar Parameters

    • Max / Min Code Length Qualification Select Max / Min Length Qualification Max Length * • Fixed Code Length Qualification Select Fixed Length Qualification Fixed Length 1 * Programming Instructions: (1) Read the label. (2) Program the desired length by reading Decimal Digits on page 52.
  • Page 20: Msi Parameters

    MSI Parameters • Checksum Verification < Single Modulo 10 > Modulo 11 & 10 • Checksum Transmission < Last digit not Transmitted > Last 2 Digits not Transmitted • Max / Min Code Length Qualification Select Max / Min Length Qualification Max Length * Programming Instructions: (1) Read the label.
  • Page 21: Ean8 Parameters

    EAN8 Parameters • Convert to EAN13 Enable • Checksum Transmission < Enable > UPCA Parameters • Convert to EAN13 < Enable > • System Number Transmission < Enable > • Checksum Transmission < Enable > Update UPCE Parameters < Disable > Disable Disable Disable...
  • Page 22: Ean13 Parameters

    EAN13 Parameters • ISBN Conversion Enable • ISSN Conversion Enable • Checksum Transmission < Enable > Update RSS Code ID Selection < Disable > RSS14 Parameters < Disable > Disable • Code ID Transmission < Enable > • Application ID Transmission <...
  • Page 23: Rss Limited Parameters

    RSS Limited Parameters • Code ID Transmission < Enable > • Application ID Transmission < Enable > • Checksum Transmission < Enable > RSS Expanded Parameters • Code ID Transmission < Enable > Update Activate Editing Formats • Format 1 Disable •...
  • Page 24: Editing Format Parameters

    Editing Format Parameters • Format Selection Format 1 Format 3 • Restore Default Format Update • Applicable Data Length Programming Instructions: (1) Read the label. (2) Program the desired length Format 2 by reading Decimal Digits on page 52. (3) Read the “Validate” label (also on page 52) to complete this setting.
  • Page 25 • Total Number of Fields Update • Applicable Code Type Clear Code 39 Italy Pharmacode French Pharmacode Industrial 25 Interleave 25 Matrix 25 Codebar Code 93 Code 128 EAN128/RSS UPCE No Addon UPCE Addon2 UPCE Addon5 EAN8 No Addon EAN8 Addon2 EAN8 Addon5 End of Format Programming...
  • Page 26 • EAN13 No Addon EAN13 Addon2 EAN13 Addon5 UPCA No Addon UPCA Addon2 UPCA Addon5 Update • Field1 Setting Programming Instructions: (1) Read the label. (2) Program the desired character string by reading Hexadecimal Digits on page 53. One character consists of 2 hexadecimal digits.
  • Page 27 • Field2 Setting Divide Field by Field Terminating String Field Terminating String * Programming Instructions: (1) Read the label. (2) Program the desired character string by reading Hexadecimal Digits on page 53. One character consists of 2 hexadecimal digits. (3) Read the “Validate” label (also on page 53) to complete this setting.
  • Page 28 • Field4 Setting Divide Field by Field Terminating String Field Terminating String * Programming Instructions: (1) Read the label. (2) Program the desired character string by reading Hexadecimal Digits on page 53. One character consists of 2 hexadecimal digits. (3) Read the “Validate” label (also on page 53) to complete this setting.
  • Page 29 • Additional Fields Setting Additional Field 1 * Additional Field 2 * Additional Field 3 * Programming Instructions: (1) Read the label. (2) Program the desired character string by reading Hexadecimal Digits on page 53. One character consists of 2 hexadecimal digits.
  • Page 30: Hexadecimal Digits

    Decimal Digits • Validate Update Hexadecimal Digits • Validate Enter Setup...
  • Page 31: Key Type

    Key Type < Normal > Key Status Add Shift Add Alternate (L) Add Alternate (R) Update KBD Wedge Character Table Scan Code Add Control (L) Add Control (R) Enter* : Enter Key of the Numeric Key Pad RS-232 Character Table "...