Advertisement

Xi2000-BT Series
Configuration Guide
POS-X, Inc.
2130 Grant St.
Bellingham, WA 98225
360-738-8533
U.S. Default Settings Sequence
• Enter Setup
• Reset Scanner
• Enable Auto-Sense Mode ON
• UPC-A Convert to EAN-13 OFF
• UPC-E Lead Zero ON
Save Changes
Exit Setup without Changes

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Xi2000-BT Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for POS-X Xi2000-BT Series

  • Page 1 U.S. Default Settings Sequence • Enter Setup • Reset Scanner • Enable Auto-Sense Mode ON Xi2000-BT Series Configuration Guide • UPC-A Convert to EAN-13 OFF • UPC-E Lead Zero ON Save Changes POS-X, Inc. 2130 Grant St. Exit Setup without Changes...
  • Page 2: Table Of Contents

    Activate Editing Formats................... 36 Table of Contents Editing Format Parameters ................37 Decimal Digits ..................... 49 Restore Default Settings ..................ii Hexadecimal Digits ..................... 50 Set Connection ......................1 RS-232 Character Table ..................51 RF Auto Shutdown Duration................1 Memory Mode Parameters ..................2 List Setting......................3 Buzzer Settings ......................3 Reading Redundancy Setting................4...
  • Page 3: Set Connection

    Memory Mode Parameters Set Connection • Memory Mode Enable Programming Instructions : (1) Read the label. (2) Read the Serial Number barcode on the bottom of the desired 3660 Base Station within 5 seconds to < Disable > complete this setting. •...
  • Page 4: Auto-Sense Setting

    List Setting Reading Redundancy Setting Page1 < No Redundancy > Page 6 2 Times Page 2 3 Times 4 Times Page 7 Scan Mode Setting Page 3 Page 8 Auto Off Mode Page 4 < Continuous Mode > Page 9 Auto Power Off Mode Page 5 Alternate Mode...
  • Page 5: Scanner Time-Out Duration

    Keyboard Wedge Parameters Scanner Time-out Duration • Activate and Select Keyboard Type Programming Instructions : (1) Read the label. (2) Program the desired time-out duration by reading Decimal Digits on page 49. (3) Read the “Validate” label (also Programming Instructions : (1) Read the label. (2) Program the desired keyboard on page 49) to complete this setting.
  • Page 6: Laptop Support

    • Keyboard Alphabets Layout • Alphabet Transmission < Default Layout > < Case Sensitive > Ignore Case AZERTY • Digits Transmission QWERTZ • Keyboard Digits Layout < Alphanumeric Key > Numeric Key < Default Layout > • Alt Composing Lower Row Upper Row •...
  • Page 7: Rs-232 Parameters

    • Flow Control RS-232 Parameters • Activate RS232 Interface < None > Scanner Ready • Baud Rate Data Ready INV. Data Ready 115200 • Inter-Character Delay 38400 19200 Programming Instructions : (1) Read the label. (2) Program the desired inter- <...
  • Page 8: Bluetooth Serial Port Parameters

    Bluetooth Serial Port Parameters Prefix / Postfix Settings • Activate BlueTooth Serial Port Interface Prefix Code * Postfix Code * • Device Name Broadcasting Character Substitution < Yes > Set 1 * Set 2 * • Authentication Set 3 * Programming Instructions : (1) Read the label.
  • Page 9: Code Id Setting

    Code ID Setting Length Code Setting (2 digits) • Code 39 Length Code Code 39 * Enable Italy Pharmacode * < Disable > French Pharmacode * • Italy Pharmacode Length Code Industrial 25 * Interleave 25 * Enable Matrix 25 * <...
  • Page 10 • Matrix 25 Length Code • Code 93 Length Code Enable Enable < Disable > < Disable > • Code 128 Length Code • Codabar Length Code Enable Enable < Disable > < Disable > • EAN128/RSS Length Code • UPCA Length Code Enable Enable <...
  • Page 11: Select Readable Codes

    • Matrix 25 Select Readable Codes • Code 39 Enable < Enable > < Disable > • Codabar Disable • Italy Pharmacode < Enable > Disable Enable • Code 93 < Disable > • French Pharmacode < Enable > Disable Enable •...
  • Page 12 • Plessey • UPCE Enable < Enable No Addon > < Disable > Disable No Addon • Telepen Enable Addon2 < Disable Addon2 > Enable Enable Addon5 < Disable > • UPCA < Disable Addon5 > • EAN8 < Enable No Addon > Disable No Addon <...
  • Page 13: Code39 Parameters

    Code39 Parameters • EAN13 • Standard / Full ASCII Code39 < Enable No Addon > < Standard > Disable No Addon Full ASCII Enable Addon2 • Start / Stop Transmission < Disable Addon2 > Enable Addon5 Enable < Disable Addon5 > <...
  • Page 14: French Pharmacode Parameters

    French Pharmacode Parameters • Max / Min Code Length Qualification • Checksum Transmission Select Max / Min Length Qualification < Enable > Disable Max Length * Min Length * Industrial 25 Parameters • Fixed Code Length Qualification • Start / Stop Selection Select Fixed Length Qualification <...
  • Page 15: Matrix 25 Parameters

    • Checksum Verification • Fixed Code Length Qualification Enable Select Fixed Length Qualification < Disable > • Checksum Transmission Fixed Length 1 * Fixed Length 2 * < Enable > Programming Instructions : (1) Read the label. (2) Program the desired length by reading Decimal Digits on page 49.
  • Page 16: Codabar Parameters

    • Max / Min Code Length Qualification • Start / Stop Selection Select Max / Min Length Qualification < abcd / abcd > abcd / tn*e Max Length * ABCD / ABCD Min Length * ABCD / TN*E • Fixed Code Length Qualification Plessey Parameters •...
  • Page 17: Msi Parameters

    • Fixed Code Length Qualification MSI Parameters • Checksum Verification Select Fixed Length Qualification < Single Modulo 10 > Fixed Length 1 * Double Modulo 10 Fixed Length 2 * Modulo 11 & 10 Programming Instructions : (1) Read the label. (2) Program the desired length by •...
  • Page 18: Ean8 Parameters

    EAN8 Parameters UPCE Parameters • Convert to EAN13 • System Number Selection Enable System Number 0 and 1 < Disable > < System Number 0 only > • Checksum Transmission • Convert to UPCA < Enable > Enable Disable < Disable > •...
  • Page 19: Ean13 Parameters

    EAN13 Parameters RSS Code ID Selection • ISBN Conversion Enable < ]e0 > < Disable > RSS14 Parameters • ISSN Conversion • Code ID Transmission Enable < Enable > < Disable > Disable • Checksum Transmission • Application ID Transmission <...
  • Page 20: Rss Limited Parameters

    RSS Limited Parameters Activate Editing Formats • Code ID Transmission • Format 1 Enable < Enable > < Disable > Disable • Application ID Transmission • Format 2 < Enable > Enable < Disable > Disable • Checksum Transmission • Format 3 <...
  • Page 21 • Applicable Data Length Editing Format Parameters • Format Selection Maximum Length * Format 1 Minimum Length * Programming Instructions : (1) Read the label. (2) Program the desired length by Format 2 reading Decimal Digits on page 49. (3) Read the “Validate” label (also on page 49) to complete this setting.
  • Page 22 • Total Number of Fields • Applicable Code Type Clear Code 39 Italy Pharmacode French Pharmacode Industrial 25 Interleave 25 Matrix 25 Codebar Code 93 Code 128 EAN128 / RSS UPCE No Addon UPCE Addon2 UPCE Addon5 EAN8 No Addon EAN8 Addon2 EAN8 Addon5 End of Format Programming...
  • Page 23 • Field1 Setting Divide Field by EAN13 No Addon Field Terminating String EAN13 Addon2 EAN13 Addon5 Field Terminating String * Programming Instructions : (1) Read the label. (2) Program the desired character UPCA No Addon string by reading Hexadecimal Digits on page 50. One character consists of 2 hexadecimal digits.
  • Page 24 • Field2 Setting • Field3 Setting Divide Field by Divide Field by Field Terminating String Field Terminating String Field Terminating String * Field Terminating String * Programming Instructions : (1) Read the label. (2) Program the desired character Programming Instructions : (1) Read the label. (2) Program the desired character string by reading Hexadecimal Digits on page 50.
  • Page 25 • Field4 Setting • Field5 Setting Divide Field by Divide Field by Field Terminating String Field Terminating String Field Terminating String * Field Terminating String * Programming Instructions : (1) Read the label. (2) Program the desired character Programming Instructions : (1) Read the label. (2) Program the desired character string by reading Hexadecimal Digits on page 50.
  • Page 26 • Additional Fields Setting • Field Transmission Sequence Start Additional Field 1 * Additional Field 4 * Field 1 Additional Field 2 * Additional Field 1 Additional Field 5 * Field 2 Additional Field 3 * Programming Instructions : (1) Read the label. (2) Program the desired character Additional Field 2 string by reading Hexadecimal Digits on page 50.
  • Page 27 Decimal Digits Hexadecimal Digits • Validate • Validate Update Enter Setup...
  • Page 28 RS-232 Character Table DLE SP " ENQ NAK % ACK SYN & < > Update...