POS-X Xi3000 User Manual

Pos-x xi3000: user guide
Hide thumbs Also See for Xi3000:

Advertisement

Table of Contents

Xi3000 Scanner
Restore Default Settings............................................................................. 1
Exit Setup without Changes....................................................................... 1
Configure Through RS232......................................................................... 1
List Setting .................................................................................................. 1
Buzzer Settings............................................................................................ 2
Reading Redundancy Setting .................................................................... 2
Scan Mode Setting ...................................................................................... 3
Scanner Time-out Duration....................................................................... 3
Negative Barcode Setting ........................................................................... 3
Delay between Reread ................................................................................ 4
Keyboard Wedge Parameters.................................................................... 4
RS-232 Parameters ..................................................................................... 8
Prefix / Postfix Settings ............................................................................ 10
Character Substitution............................................................................. 10
Code ID Selection ..................................................................................... 10
Code ID Setting......................................................................................... 11
Length Code Setting (2 digits) ................................................................. 12
Select Readable Codes.............................................................................. 15
Code39 Parameters .................................................................................. 19
Italy Pharmacode Parameters ................................................................. 19
French Pharmacode Parameters............................................................. 20
Industrial 25 Parameters ......................................................................... 20
Interleave 25 Parameters ......................................................................... 21
Matrix 25 Parameters .............................................................................. 23
Codabar Parameters ................................................................................ 24
Plessey Parameters ................................................................................... 25
MSI Parameters........................................................................................ 26
EAN128 Parameters ................................................................................. 27
EAN8 Parameters ..................................................................................... 28
UPCA Parameters .................................................................................... 28
UPCE Parameters..................................................................................... 29
User's Manual
EAN13 Parameters ................................................................................... 30
Activate Editing Formats......................................................................... 31
Editing Format Parameters ..................................................................... 32
Decimal Digits ........................................................................................... 44
Hexadecimal Digits ................................................................................... 45
Key Type.................................................................................................... 46
Key Status.................................................................................................. 46
KBD Wedge Character Table ................................................................. 47
RS-232 Character Table .......................................................................... 47

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Xi3000 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for POS-X Xi3000

  • Page 1: Table Of Contents

    Table of Contents Xi3000 Scanner Restore Default Settings... 1 Exit Setup without Changes... 1 Configure Through RS232... 1 List Setting ... 1 Buzzer Settings... 2 Reading Redundancy Setting ... 2 Scan Mode Setting ... 3 Scanner Time-out Duration... 3 Negative Barcode Setting ... 3 Delay between Reread ...
  • Page 2: Restore Default Settings

    Restore Default Settings Exit Setup without Changes Configure Through RS232 List Setting Page1 Page 2 Page 3 Page 4 Page 5 Update Buzzer Settings • Buzzer Frequency Reading Redundancy Setting Page 6 Page 7 Page 8 Page 9 Page 10 <...
  • Page 3: Scan Mode Setting

    Auto Power Off Mode Momentary Mode Laser Mode Scanner Time-out Duration Programming Instructions : (1) Read the label. (2) Program the desired time-out duration by reading Decimal Digits on page 44. (3) Read the “Validate” label (also on page 44) to complete this setting.
  • Page 4 • Keyboard Table Keyboard Type PCAT (US) PCAT (French) PCAT (German) PCAT (Italy) PCAT (Swedish) PCAT (Norwegian) PCAT (UK) PCAT (Belgium) PCAT (Spanish) PCAT (Portuguese) PS55 A01-1 PS55 A01-2 PS55 A01-3 PS55 001-1 PS55 001-81 PS55 001-2 PS55 001-82 PS55 001-3 PS55 001-8A PS55 002-1, 003-1 PS55 002-81, 003-81...
  • Page 5: Rs-232 Parameters

    • Alphabet Transmission < Case Sensitive > • Digits Transmission < Alphanumeric Key > • Alt Composing • Inter-Character Delay Programming Instructions : (1) Read the label. (2) Program the desired inter- character delay by reading Decimal Digits on page 44. (3) Read the “Validate” label (also on page 44) to complete this setting.
  • Page 6: Prefix / Postfix Settings

    Decimal Digits on page 44. (3) Read the “Validate” label (also on page 44) to complete this setting. Update Prefix / Postfix Settings Scanner Ready Character Substitution INV. Data Ready Programming Instructions : (1) Read the label. (2) Program the desired character string by reading Hexadecimal Digits on page 45.
  • Page 7: Code Id Setting

    Code ID Setting Code 39 * French Pharmacode * Interleave 25 * Codabar * UPCE * EAN13 * Code 128 * Plessey * Programming Instructions : (1) Read the label. (2) Program the desired character string by reading Hexadecimal Digits on page 45. One character consists of 2 hexadecimal digits.
  • Page 8 • Matrix 25 Length Code Enable • UPCA Length Code Enable • UPCE Length Code Enable • EAN8 Length Code Enable • EAN13 Length Code Enable • Code 93 Length Code Enable Update < Disable > < Disable > < Disable > <...
  • Page 9: Select Readable Codes

    Select Readable Codes • Code 39 < Enable > • Italy Pharmacode Enable • French Pharmacode Enable • Industrial 25 < Enable > • Interleave 25 < Enable > Update Disable < Disable > < Disable > Disable Disable • Matrix 25 Enable •...
  • Page 10 • Plessey Enable • UPCA < Enable No Addon > Disable No Addon Enable Addon2 < Disable Addon2 > Enable Addon5 < Disable Addon5 > • UPCE < Enable No Addon > Disable No Addon Enable Addon2 < Disable Addon2 > Enable Addon5 <...
  • Page 11: Code39 Parameters

    Code39 Parameters • Standard / Full ASCII Code39 < Standard > • Start / Stop Transmission Enable • Checksum Verification Enable • Checksum Transmission < Enable > Italy Pharmacode Parameters • Checksum Transmission < Enable > Update French Pharmacode Parameters Full ASCII Industrial 25 Parameters <...
  • Page 12: Interleave 25 Parameters

    • Max / Min Code Length Qualification Select Max / Min Length Qualification Max Length * • Fixed Code Length Qualification Select Fixed Length Qualification Fixed Length 1 * Programming Instructions : (1) Read the label. (2) Program the desired length by reading Decimal Digits on page 44.
  • Page 13: Matrix 25 Parameters

    • Fixed Code Length Qualification Select Fixed Length Qualification Fixed Length 1 * Programming Instructions : (1) Read the label. (2) Program the desired length by reading Decimal Digits on page 44. (3) Read the “Validate” label (also on page 44) to complete this setting.
  • Page 14: Plessey Parameters

    • Start / Stop Selection < abcd / abcd > ABCD / ABCD Plessey Parameters • Convert to UK Plessey Enable • Checksum Transmission < Enable > Update MSI Parameters abcd / tn*e ABCD / TN*E < Disable > Disable Programming Instructions : (1) Read the label.
  • Page 15: Ean128 Parameters

    • Fixed Code Length Qualification Select Fixed Length Qualification Fixed Length 1 * Programming Instructions : (1) Read the label. (2) Program the desired length by reading Decimal Digits on page 44. (3) Read the “Validate” label (also on page 44) to complete this setting.
  • Page 16: Upce Parameters

    UPCE Parameters • System Number Selection System Number 0 and 1 < System Number 0 only > • Convert to UPCA Enable • System Number Transmission Enable • Checksum Transmission < Enable > Update EAN13 Parameters < Disable > < Disable > Disable •...
  • Page 17: Activate Editing Formats

    Activate Editing Formats • Format 1 Enable • Format 2 Enable • Format 3 Enable • Exclusive Data Editing Update Editing Format Parameters < Disable > < Disable > < Disable > < No > • Format Selection Format 1 Format 3 •...
  • Page 18 • Applicable Data Length Maximum Length * Programming Instructions : (1) Read the label. (2) Program the desired length by reading Decimal Digits on page 44. (3) Read the “Validate” label (also on page 44) to complete this setting. • Matching String of Applicable Data Programming Instructions : (1) Read the label.
  • Page 19 • Applicable Code Type Code 39 Italy Pharmacode French Pharmacode Interleave 25 Codebar Code 128 UPCE No Addon UPCE Addon5 EAN8 No Addon EAN8 Addon2 Update Clear Industrial 25 Matrix 25 Code 93 EAN128 UPCE Addon2 EAN8 Addon5 EAN13 No Addon EAN13 Addon2 EAN13 Addon5 UPCA No Addon...
  • Page 20 • Field1 Setting Divide Field by Field Terminating String Field Terminating String * Programming Instructions : (1) Read the label. (2) Program the desired character string by reading Hexadecimal Digits on page 45. One character consists of 2 hexadecimal digits. (3) Read the “Validate” label (also on page 45) to complete this setting.
  • Page 21 • Field3 Setting Divide Field by Field Terminating String Field Terminating String * Programming Instructions : (1) Read the label. (2) Program the desired character string by reading Hexadecimal Digits on page 45. One character consists of 2 hexadecimal digits. (3) Read the “Validate” label (also on page 45) to complete this setting.
  • Page 22 • Field5 Setting Divide Field by Field Terminating String Field Terminating String * Programming Instructions : (1) Read the label. (2) Program the desired character string by reading Hexadecimal Digits on page 45. One character consists of 2 hexadecimal digits. (3) Read the “Validate” label (also on page 45) to complete this setting.
  • Page 23: Decimal Digits

    • Field Transmission Sequence Start Field 1 Field 2 Field 3 Field 4 Field 5 Field 6 Programming Instructions : (1) Read the “Start” label. (2) Program the desired transmission sequence by reading the Field / Additional Field labels. (3) Read the “End”...
  • Page 24: Hexadecimal Digits

    Hexadecimal Digits • Validate Update Key Type Key Status < Normal > Scan Code Add Shift Add Control (L) Add Alternate (L) Add Control (R) Add Alternate (R) Enter Setup...
  • Page 25: Kbd Wedge Character Table

    KBD Wedge Character Table " 3 Home F5 6 Down F8 & Left Right ESC C PgUp Exec < Enter PgDn > Dly Enter* Dly : Delay 100 ms Enter* : Enter Key of the Numeric Key Pad … : Digits of Numeric Key Pad RS-232 Character Table DLE SP "...

Table of Contents