Water Connections; Electrical Connections - Taylor MagnaBlend SB25 Operator's Manual

Blended ice machine
Hide thumbs Also See for MagnaBlend SB25:
Table of Contents

Advertisement

TO THE INSTALLER
comply with applicable national, state, and local codes.
Water temperature is not to exceed 125°F (51°C). Water
pressure to the machine must be 55 psi to 100 psi
(379 kPa to 690 kPa).

Water Connections

1
An adequate cold water supply must be provided with a
hand shutoff valve. Depending on local water conditions,
it may be advisable to install a water strainer to prevent
foreign substances from clogging the water valve.
IMPORTANT! A backflow prevention device is
required on the incoming water connection side of the
machine. Please refer to the applicable national, state,
and local codes for determining the proper configuration.
All connections to the main water source must be
performed by a licensed plumbing professional and meet
all national, state, and local codes.
The potable water source should be filtered.
Water pressure to the machine should range from 55 psi
to 100 psi (379 kPa to (690 kPa).
Hot or cold water may be used. Hot water is
recommended for better rinsing. The temperature must
not exceed 120°F (49°C).
The water line must be equipped with a manual shutoff
valve to stop water flow in case of emergency or if repairs
are necessary.
1-2
Drain Hose Connection
The drain hose must be attached to the drain port
connection on the bottom of the machine. Position the
drain hose downward for maximum water flow.
Locate the nearest drain that can accommodate a 1-1/8
in. (28.575 mm) diameter drain tube. A minimum of 1 in.
(25 mm) air gap is required between the end of the drain
tube and the drain to ensure proper flow. The drain tube
must not be submerged.
Important! Machine must be installed on a level surface
for proper drainage.
Note: Machines equipped with the optional Rinse
Station do not require a drain tube be connected directly
to the machine and the drain pan should be removed.
Attach the drain tube to the rinse station.

Electrical Connections

In the United States, this machine is intended to be
installed in accordance with the current edition of the
National Electrical Code (NEC), ANSI/NFPA 70, which
governs the installation of the machine at the local
governmental level.
The purpose of the NEC code is the practical
safeguarding of persons and property from hazards
arising from the use of electricity. This code contains
provisions considered necessary for safety.
In all other areas of the world, the machine should be
installed in accordance with existing local codes. Please
contact your local authorities.
Each machine requires one power supply for each data
label on the machine. Check the data label(s) on the
machine for branch circuit overcurrent protection or fuse,
circuit ampacity, and other electrical specifications. Refer
to the wiring diagram provided inside of the electrical box
for proper power connections.
FOLLOW YOUR LOCAL ELECTRICAL CODES.
WARNING! This machine must be properly
grounded. Failure to do so can result in severe personal
injury from electrical shock.
Model SB25
To the Installer

Advertisement

Table of Contents
loading