ADJUSTING THE TEMPERATURE DIFFERENTIAL
HEAT DIFFERENTIAL OR SWING
Select HEAT with the system switch, hold down the + and - buttons together
for 3 seconds to access the HEAT SWING setting. Use the + or - key to adjust
the swing from ±0.2°F to ±2°F. Wait approximately 15 seconds or slide the
system switch to return to normal operation
COOL DIFFERENTIAL OR SWING
Select COOL with the system switch, hold down the + and - buttons together
for 3 seconds to access the COOL SWING setting. Use the + or - key to
adjust the swing from ±0.2°F to ±2°F. Wait approximately 15 seconds or slide
the system switch to return to normal operation.