This passport is a document certifying the main parameters and technical
characteristics of the CPFM-Tester OS.25-02 guaranteed by the manufacturer
This passport allows you to get acquainted with the device, the procedure and
rules for its operation, compliance with which will ensure the correct operation of the
device.
The CPFM-Tester device is designed to test and verify the performance of
diesel injection pumps (high pressure fuel pumps) of the Common Rail system.
The device has two channels for measuring the strait. In each meter (sensor)
of the strait is a temperature sensor that measures the temperature of the liquid
(flow).
• Range of the measured stream: 0,05 - 20 l / min;
• Range of the measured stream: 3–1200 l / hour;
• Accuracy of flow measurement, in the range of 10-150l / hour, not
more than: +/- 2l / hour;
• Accuracy of flow measurement, in the range up to 10 and more than
150 l / h: not more than 1%;
• Permissible temperature range of the measured flow: -20 - +90 ° C;
• Error of measurement of temperature of a stream, no more: +/- 2 ° C;
• Supply voltage: ~ 220 V ± 15%;
• Mass of the device: 6 kg;
• Dimensions (length x width x height): 320x285x80;
• Power consumption, no more: 24 W.
Introduction
2. Basic technical data and specifications
1. Purpose
Need help?
Do you have a question about the CPFM-Tester and is the answer not in the manual?
Questions and answers