DEFINITIONS FOR ILLUMINATED LCD INDICATORS

1. ONLINE:
The UPS is supplying utility power to
connected equipment.
2. BATTERY:
During a severe brownout or blackout,
this icon appears and an alarm sounds
(two short beeps followed by a pause)
to indicate the UPS is operating from its
internal batteries. During a prolonged
brownout or blackout, the alarm will beep
rapidly every 1/2 second to indicate the
UPS's batteries are nearly out of power.
You should save files and turn off your
equipment immediately or allow the
software to shut the system down.
3. ENERGY-SAVING:
The UPS in energy-saving bypass mode.
See "CyberPower GreenPower UPS
Technology" section for more information.
4. LOAD CAPACITY/SENSITIVITY SETUP:
LOAD capacity: This meter displays the
approximate output load level (in 20%
increments) of the UPS battery outlets.
Sensitivity setup: This meter is also used to
setup the UPS sensitivity when you are in
the programming mode. If the connected
equipment can tolerate more power
events (example: unstable power often
associated with stormy weather), select
Low Sensitivity and the UPS will go to
Battery Mode less often. If the connected
equipment is more sensitive to power
events, select High Sensitivity and the UPS
will go to Battery Mode more often.
5. BATTERY CAPACITY:
This meter displays the approximate
charge level (in 20% increments) of the
UPS's internal battery. During a blackout
or severe brownout, the UPS switches to
battery power, the BATTERY icon appears,
and the charge level decreases.
6. FAULT:
This icon appears if there is a problem with
the UPS. Press the POWER button to turn
the UPS off.
F01: Battery Mode or AC/Utility Power
Mode Overload fault (Unplug at least one
piece of equipment from battery outlets
and turn the UPS on again.)
F02: Battery Output Short fault (Unplug at
least one piece of equipment from battery
outlets and turn the UPS on again.)
F03: Charger Fault (Contact CyberPower
Systems for support.)
12
11
10
9
F04: Internal Fault (Contact CyberPower
Systems for support.)
TM
7. OVERLOAD:
This icon appears and an alarm sounds to
indicate the battery-supplied outlets are
overloaded. To clear the overload, unplug
one piece of equipment from the battery-
supplied outlets at a time until the icon
turns off and the alarm stops.
8. SCHEDULE:
Users can setup the schedule to turn on
and shut down the computer and UPS
through PowerPanel® Personal software.
The LCD display will show how much time
is left before the UPS will turn back on or
shut down.
9. ESTIMATED RUNTIME:
This displays the run time estimate of the
UPS with current battery capacity and load.
10. OUTPUT METER:
This meter measure, in real time, the AC
voltage that the UPS system is providing
to the computer, such as normal AC line
mode, AVR mode, and battery backup
mode. (Note: The OUTPUT meter shows
the status of the battery backup outlets in
terms of load, frequency, and voltage.)