− the regulations of the electrical power supply company or agency;
− any other local prescriptions.
1.6
SPECIAL REQUIREMENTS FOR THE INSTALLATION SITE
− The room in which the appliance is to operate must be well ventilated.
− In addition, it is good policy to locate the appliance under an extractor hood so that cooking vapours can
be removed rapidly and continuously.
− To connect directly to the network, it is necessary to provide a device ensuring disconnection to the
network, with a opening gap of contacts that allows complete disconnection in the conditions of
overvoltage category III in accordance with the rules of installation.
− This appliance requires one water connection. The line must be fitted with an on-off valve.
The electrical isolating switch and the water shutoff valves must both be located near
to the appliance, within easy reach for the user.