Download Print this page

Mistral FBF 2.0 Manual page 10

Advertisement

Available languages

Available languages

Hygiene kit replacement
HYGIENE KIT REPLACEMENT (operation to be made every 3 months)
1. Disconnect the power cable of the water cooler.
2. Remove the bottle.
3. Press on the cold tap to empty the water inside the reservoir.
4. Push the lock located on the cooler's top to open the water cooler.
5. Press on the distribution taps to remove the tubes from their location.
6. Remove the hygiene kit.
7. Replace the hygiene kit.
Water-heater discaling
As manufacturer we recommend a discaling of water-heater once a year to ensure the mate-
riel's life.
1. Press on the ON-OFF button to switch off the water-heater and disconnect the power cable of
the machine (figure 1).
2. Remove the bottle (figure 2).
3. Take a 2L bucket (figure 4) & place it under the draining cap of the water heater located behind
the cooler. Unscrew the draining cap (+ remove the red cap) and empty a cup of 20cl.
CAUTION : Burn Hazard - The water is extremely hot.
4. Replace de draining cap without forget the red cap.
5. Open the top panel (figure 3) & remove the hot adaptor of the hygiene kit by pulling on the re-
ceptacle(figure 5). Put a funnel on adaptor's place (figure 6).
6. Prepare 20cl of descaling solution diluted with water and pour the preparation in the water
heater via the funnel. Wait around 5 minutes.
7. Unscrew the draining cap (+ remove the red cap) and empty the water heater. Then replace the
two draining caps.
8. Install a new hygiene kit, close the top panel & replace the bottle.
9. Via the distribution, flush around 2 liters by pressing on the hot water tap.
10. Reconnect the water cooler and switch on the water heater's button.
figure 1
figure 2
figure 3
figure 4
- page 10 -
figure 5
figure 6

Advertisement

loading

This manual is also suitable for:

Fbm 2.0