GENERATOR SYSTEM
I
ELEC
I
u
I
TROUBLESHOOTING
1. AC generation is not normal
Check output voltage at AC
Lr
Check AC receptacle with its ter-
receptacle.
minals connected with a wire.
0-15V
Conducting
I
Faulty voltmeter or faulty load.
Specified reading
Not conducting
Low reading
~
Unusually
40-60V
In-between
~
high reading
reading
l
Faulty AC receptacle
Reset governor arm/ shaft.
I
Check engine revolutions.
(i.e. frequency)
Turn adjust bolt anticlockwise,
r
More than 3,800 rpm.
observing engine revolutions.
L
Too low
Normal
Stay unchanged
I
Return to normal
l
Check wiring harness
fo~
continuity:
Check AC protector
Faulty adjust plate or faulty
Conducting
Not conducting
Conducting
I
Not conducting
governor.
l
Faulty AC protector
1--
Check resistance in main coil.
~~
Faulty wiring harness
I
Check resistance in sub-coil.
Infinity or below standard
Standard resistance fl ± 10%
Standard resistance fl ± 10%
120V
11--r
o;=oooc<;oo"' •hort-ok'";' ;,
f . - - -
..---
60Hz
120V
main coil. Replace it.
f-----
1---L,__
I - -
~
60Hz
1 - - -
Infinity or below standard.
1.764
+
I
Replace the stator assembly
I
Check condenser characteristics
NOTE:
Check for internal grounding of win-
(Characteristics)
If a digital meter is used, the rise on
dings in main coil and sub coil.
,
__
With tester set to (R x 100), its nee-
readings may be slow, with quick
I
Not continuity
die must swing sharply away and
drop-off to "OPEN" reading.
Continuity
back the moment lead wire touches
~
condenser terminal.
r - -
Does not swing
Swings
I
Faulty coil
I
In checking rectifier, connect tester
lead wires to respective rectifier
Condenser punctured or
~
terminals.
deteriorated. Replace it.
Check rotor rectifier.
Rectifier must have one-way
continuity.
Resistance
I
Normal direction
Continuity
I
NOTE:
I
Reverse direction
No continuity
I
Measure after disengaging from field
I
Faulty rectifier.
coil. Reverse tester leads, there
Not normal
Normal
should be no continuity.
Replace it.
Check resistance in rotor (field) coil.
Standard value
Check for internal grounding of rotor
For magnetizing:
4.11fl±10%
windings.
Start engine and let both terminals
Infinity or below standard
Continuity
I
No continuity
of condenser lightly contact cor-
t
responding terminals of lead wires
from 12V battery.
i
Disconnection or short-circuit in field
coil. Replace it.
Faulty rotor coil
I
Demagnetized rotor
Magnetized rotor
4-7