TABLE OF CONTENTS General Information Description Identification Damage Damage Claim Procedure Installation General Information Inspection Data Cable Installation Electrical Connection Control Console Operation Scoreboard Power Control Console Display Control Console Power Initializing Scoreboard Time Setting and Control Team Scores Horn (Optional) Period Indicators Dimmer 3.10 Track Operation...
1. GENERAL INFORMATION 1.1 DESCRIPTION Your All-American scoreboard has been carefully inspected and tested before leaving the factory. It is possible, however, that components may be loosened or forced out of adjustment in transit. If this occurs, follow the troubleshooting guide (section 4). If equipment then fails to operate, contact immediately: ALL-AMERICAN Service Department EVERBRITE LLC...
If damage is discovered after delivery, you should call the delivery company. Have them make out a Concealed Damage Report. Fifteen days after delivery are allowed, so this should be done promptly or it is impossible to process this claim. Advise EVERBRITE corporation of necessary replacement parts, or repairs.
2.2 Inspection Inspect each unit and tighten all screws, lamps, and fittings that may have loosened in shipment. 2.3 Data Cable Installation The MP-41 data cable carries only low voltage signals and therefore can be installed with or without conduit. consult section 6 for junction box and scoreboard wiring. 2.4 Electrical connections This scoreboard requires one 120 V.
SCOREBOARD CONTROL 1991 VERSION 3.3 3.4 Initializing Scoreboard Enter the two digit code (58) shown in the lower left corner of the keyboard as in the following example: Push CODE ENTER . When the proper code has been entered, the console display will show as follows. The scoreboard display will now show :00 in the time section.
Push: ROUND ENTER . (C) To clear the round: Push ROUND CLEAR . 3.7 Selection Selection is controlled in a similar manner as round. 3.8 Horn (Optional) The horn will blow for 1/2 second each time HORN is pressed. The horn will blow automatically at the end of each period for 2 seconds. The automatic horn function may be disabled by using the AUTO HORN key.
Page 8
(A) Scoreboard doesn't light and console doesn't work (a) Check that the main power switch is turned on. (b) Replace any defective or blown fuses. (c) Check the power connections and voltages at the scoreboard. (d) Contact the customer service department. (B) Scoreboard digits don't light, but the console works (a) With the main power switch "off";...
Page 9
EXAMPLE: Plug "C" into "D" and "D" into "C" locations. (b) Turn the power back on. If the same lamps remain lit all the time, the problem is a shorted lamp socket. If the lamps on a different digit now stay lit all the time, the problem is on the driver PCB assembly.
5. REPLACEMENT PARTS LIST 5.1 Scoreboard Display Parts figure 1 DISPLAY ASSEMBLY...
Page 11
REPLACEMENT PARTS LIST (MP-34XX NFL Timer) fig.& MFG PART VENDOR index NUMBER DESCRIPTION PART # 000000 Display Assembly 000000 850000 Lamp, 7W/125V Red 7C7 R 850001 Lamp, 7W/125V White 7C7 W 850002 Lamp, 7W/125V Orange 7C7 O SU479300X Controller Assembly, MP-34XX NFL SU479300X *****SEE DETAIL FIGURE 2***** 119337...
Page 20
8 BIT FIGUREGRAM WIRING 6.8 Jumper Location on 3 Position System All of the 3 position drivers and receivers are identical except for the jumper on each board. Make sure the jumpers are set for the model of scoreboard you are installing them into. (A) On the receiver board (refer to figure);...
Page 21
JUMPER LOCATION 6.9 Triac Placement The triac is the switch that controls the figuregram lamps. The triacs for any given figuregram are adjacent to the twelve pin connector on the driver board that controls that figuregram. Shown below is the triac placement and bit designation relative to the figuregram bit pattern. MP TRIAC PLACEMENT...