TABLE OF CONTENTS General Information Description Identification Damage Damage Claim procedure Installation General Information Inspection Pre-Test Installation Electrical Connection Control Console Operation Display Power Control Console Power Control Console Display Display Control Dimmer Maintenance And Troubleshooting Introduction Test Equipment Troubleshooting Troubleshooting Guide Replacement Parts List Display Parts...
1. GENERAL INFORMATION 1.1 DESCRIPTION Your All-American scoreboard has been carefully inspected and tested before leaving the factory. It is possible, however, that components may be loosened or forced out of adjustment in transit. If this occurs, follow the troubleshooting guide (section 4). If equipment then fails to operate, contact immediately: ALL-AMERICAN Service Department EVERBRITE LLC...
If damage is discovered after delivery, you should call the delivery company. Have them make out a Concealed Damage Report. Fifteen days after delivery are allowed, so this should be done promptly or it is impossible to process this claim. Advise EVERBRITE corporation of necessary replacement parts, or repairs.
2.3 Pre-Test Before installing the counter, pre-test all functions. 2.4 Installation Select the location best suited for visibility by the majority of spectators. Preferred position is facing east or north to avoid direct sunlight on the face of the scoreboard, if day use is planned. The MP-40 direct burial data cable carries only low voltage signals and therefore can be installed with or without conduit.
Enter the two digit code (94) as in the following example: Push CODE ENTER . When the proper code has been entered, the console display will show "0" . 3.3 Console Display The Liquid Crystal Display (LCD) shows what the counter shows. 3.4 Black Flag Control The Black Flag Number can be changed in following ways.
IMPORTANT !!! In this scoreboard the 120 volt line is on the lamp socket all the time, and the common is switched to turn the lamps on and off. For this reason, to avoid damage to the equipment or personal injury, it is important to turn the main power off when changing the lamps.
Page 8
(C) The scoreboard digits light but the console doesn't work (a) Check for continuity between the scoreboard and the junction box. (b) If an open circuit is found, the problem is either the cable or a cable connection. (c) If the continuity test checks good, check the voltage between the green wire and the white wire in the junction box, using a voltmeter set on the 12 VAC or higher scale.
5.2 Controller Assembly Parts figure 2 CONTROLLER ASSEMBLY REPLACEMENT PARTS LIST (MP-3804 Controller Assembly) fig.& MFG PART VENDOR index NUMBER DESCRIPTION PART # 150624X Controller Assembly 150624X 119323 Receiver PCB Assembly 119323 ***** PROGRAM RX2 TIME V1.10 ***** 118922 Driver PCB Assy, 3 Position #1 118922 2-2A 930674...
Page 19
6.8 Jumper Location on 3 Position System All of the 3 position drivers and receivers are identical except for the jumper on each board. Make sure the jumpers are set for the model of scoreboard you are installing them into. On the receiver board (refer to figure);...
JUMPER LOCATION 6.9 Triac Placement The triac is the switch that controls the figuregram lamps. The triacs for any given figuregram are adjacent to the twelve pin connector on the driver board that controls that figuregram. Shown below is the triac placement and bit designation relative to the figuregram bit pattern.