TYPE OF
CODE
ANOMALY
ALARM
Stops food
Eprb5
probe cycles
only if the entire
sensor is faulty
ALARM
Stops food
Eprb6
probe cycles
only if the entire
sensor is faulty
ALARM
B4
Stops machine
Ertc
WARNING
ECHt
WARNING
ALARM
E11
Stops machine
ERROR
B2
Stops cycle
ALARM
ACUP
Stops machine
DESCRIPTION
POSSIBLE CAUSES
• Food probe misuse (for exam-
ple, wire pulled or squeezed)
Core probe fail-
• Connector failure
ure sensor n°5
• Probe failure
• PCB failure
• Food probe misuse (for exam-
ple, wire pulled or squeezed)
Core probe fail-
• Connector failure
ure sensor n° 6
• Probe failure
• PCB failure
• Power supply missing
Supply power
• Supply power system failure
missing
• Other electrical issues (for
example current dispersions)
• Battery of User interface is low
Low battery
• Electronic board failure
• Door left open
Cavity high
• Food too hot in the cavity
temperature
• Issue with parameter ady or
with temperature measurement
• Fan condenser overload (exam-
ple: room temperature too high)
• Electrical issue (example: con-
Compressor
nector unplugget)
failure
• Gas leak
• Compressor damaged
• The door remained open
beyond the time limit set whit
Door open
the active cycle
• Door closure recognition system
is failed
• ACU board not programmed or
ACU protocol
programmed with an incompat-
error
ible Software version
• Electronic boards disconnected
ACTIONS
• Current running cycle:
a) the cycle continues in probe
mode until at least one out of the 6
food probe points is working.
b) the cycle switches to time mode
if none out of the 6 food probe
points is working.
• During STANDBY:
a) the cycle can be started until at
least one point is working.
b) the cycle can be started in time
mode in case all points are failed.
• To restore full functionality, call
Service.
• Current running cycle:
a) the cycle continues in probe
mode until at least one out of the 6
food probe points is working.
b) the cycle switches to time mode
if none out of the 6 food probe
points is working.
• During STANDBY:
a) the cycle can be started until at
least one point is working.
b) the cycle can be started in time
mode in case all points are failed.
• To restore full functionality, call
Service.
• Current running cycle: the cycle
restarts automatically when the
power is back.
• The machine was not in operation
for a certain period of time: check
initial and end time.
• Check the plug or general electric
control panel.
• If the alarm reoccurs, Call Service.
Problem with battery of internal clock.
Functions related to the clock will not
operate (example: HACCP event
recording will be wrong).
CALL SERVICE
• The cavity temperature has
exceeded the set limit, in additional
to the signal delay time.
• Current running cycle: the cycle
continues.
• If the alarm persists even if the
cavity temperature is low, call
service.
• The chiller will be blocked and only
fan condenser runs.
• Check if there is any obstruction at
the suction air condenser.
CALL SERVICE
• Ensure the chiller door is closed
and any physical obstruction is not
preventing the door closure.
• Start new cycle: if either a new
cycle will not start or the alarm
persists even with the door closed,
Call Service.
• Communication protocol error
detected.
• If the problem persists, Call Service.