9. TROUBLESHOOTING

PROBLEM
REASON
Machine refuses to run
Machine not plugged in
Defective socket
Fuse has blown
Defective extension cable
Fluctuating pressure
Pump sucking air
Valves dirty, worn or stuck
Pump seals worn out
Machine stops
Fuse has blown
Incorrect mains voltage
Thermal sensor activated
Nozzle partially blocked
Fuse blows
Fuse too small
Machine pulsating
Air in inlet hose/pump
Inadequate supply of mains water
Nozzle partially blocked
Water filter blocked
Hose kinked
Machine often starts
Pump/hose or accessory frozen
and stops by itself
No water supply
Water filter blocked
Nozzle blocked
Machine starts, but no
Pump/hose or accessory
water comes out
frozen
No water supply
Water filter blocked
Nozzle blocked

ENVIRONMENT PROTECTION

Recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be sorted, taken to
a recycling centre and disposed of in a manner which is compatible with the environment. When the product becomes completely
unserviceable and requires disposal, drain any fluids (if applicable) into approved containers and dispose of the product and fluids
according to local regulations.
WEEE REGULATIONS
Dispose of this product at the end of its working life in compliance with the EU Directive on Waste Electrical and Electronic Equipment
(WEEE). When the product is no longer required, it must be disposed of in an environmentally protective way. Contact your local solid
waste authority for recycling information.
Note: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts
without prior notice.
Important: No Liability is accepted for incorrect use of this product.
Warranty: Guarantee is 12 months from purchase date, proof of which is required for any claim.
Sealey Group, Kempson Way, Suffolk Business Park, Bury St Edmunds, Suffolk. IP32 7AR
01284 757500
© Jack Sealey Limited
ACTION
Plug in machine
Try another socket
Replace fuse
Try without extension cable
Check that hoses and connections are airtight
Clean and replace or return for repair
Clean and replace or return for repair
Replace fuse. Switch off other machines
Check that the mains voltage corresponds to specification on the model tag
Leave the washer for 5 minutes to cool down
Clean the nozzle
Change to an installation higher than the amps consumption of the machine
Try without an extension cable
Allow machine to run with open trigger until regular working pressure resumes
Check that the water supply corresponds to specifications required
Clean the nozzle
Clean the filter
Straighten out hose
Wait for pump/hoses or accessory to thaw
Connect inlet water
Clean the filter
Clean the nozzle
Wait for pump/hoses or accessory to thaw
Connect inlet water
Clean the filter
Clean the nozzle