Quick Installation Guide
Version 1.0
S6-GR1P(7-8)K2
Ginlong Technologies Co., Ltd.
Note:
Installation Manual Download
For access to the manual please scan
the QR code below or you can go the URL
https://www.ginlong.com/global/
service.html
After entering the page, you can click "
icon to change to preferred language.
1
Bottom of the Inverter
Some models may have a different number of DC inputs,
please refer to datasheet/nameplate/actual product.
DC Switch(optional)
CT or meter input
DC input
RS 485
DRM
If no PV string connects to the DC input terminals, please install
the watertight cap onto the empty DC input terminals to guarantee
the inverter ingress protection rating.
2
Installation Clearance
Minimum clearance is required.
300mm
300mm
3
Mounting Hole Size
Use a 10mm drill bit to drill a hole of 60mm depth.
"
4
Inverter Installation
AC output
Ensure the mounting bracket is horizontal and use a Phillips
screwdriver to fasten the expansion bolts.
Lift the inverter and hang it on the bracket.
5
DC Connector Wiring and Assemble
Use a wire crimper to fasten the metal connector and insert it
into the top of the AMPHENOL connector. Use the AMPHENOL
special tool to fasten the AMPHENOL assembly.
outer diameter
2.5-4mm²
outer diameter
300mm
2.5-4mm²
Crimping plier
Locking screws
7±0.5mm
7±0.5mm
Note: Locator wings should not be crimped
AMPHENOL special tool
(-)
(+)