Gas interface

2.
Connect the cutting gas pipe to the cooling gas pipe of the nozzle and tighten it with
a wrench.
Note: When using
φ 12 air pipe, the
air pipe interface
of
φ 12 in the
fitting box needs to
be replaced.
Cutting
Interface
Note: When using
φ12 air pipe, the
air pipe interface
of φ12 in the
fitting box needs to
be replaced.
tallation connection: cutting gas 1,
Ins
nozzle cooling gas 2
Notice:
The maximum pressure of cutting gas is 25bar (2.5Mpa).
The cutting gas quality shall meet the requirements of gas quality in accordance with ISO
8573-1:2010: solid particles - class 2, water - class 4, oil - class 3. The purer the cutting gas,
the longer the life of the protective lens.
The cutting gas pipe diameter (outer diameter) is 10mm, and the nozzle cooling gas pipe
diameter (outer diameter) is 8mm.