Nordson iTrax Customer Product Manual
Nordson iTrax Customer Product Manual

Nordson iTrax Customer Product Manual

Pc pedestal
Hide thumbs Also See for iTrax:

Advertisement

Quick Links

iTrax
PC Pedestal
®
Customer Product Manual
Document Number

1617371-01
Issued 03/22
For parts and technical support, call the Industrial Coating
Systems Customer Support Center at (800) 433-9319 or
contact your local Nordson representative.
This document is subject to change without notice.
Check
http://emanuals.nordson.com
for the latest version.
NORDSON CORPORATION • AMHERST, OHIO • USA

Advertisement

Table of Contents
loading

Summary of Contents for Nordson iTrax

  • Page 1 For parts and technical support, call the Industrial Coating Systems Customer Support Center at (800) 433-9319 or contact your local Nordson representative. This document is subject to change without notice. Check http://emanuals.nordson.com for the latest version. NORDSON CORPORATION • AMHERST, OHIO • USA...
  • Page 2: Table Of Contents

    Nordson Corporation welcomes requests for information, comments, and This is a Nordson Corporation publication which is protected by copyright. inquiries about its products. General information about Nordson can be found on Original copyright date 2022. No part of this document may be photocopied,...
  • Page 3 Change Record Change Record Revision Date Change 03/22 Initial Release 1617371-01 © 2022 Nordson Corporation...
  • Page 4 Change Record 1617371-01 © 2022 Nordson Corporation...
  • Page 5: Safety

    Intended Use Use of Nordson equipment in ways other than those described in the documentation supplied with the equipment may result in injury to persons or damage to property. Some examples of unintended use of equipment include: •...
  • Page 6: Personal Safety

    PC Pedestal Personal Safety To prevent injury follow these instructions. • Do not operate or service equipment unless you are qualified. • Do not operate equipment unless safety guards, doors, or covers are intact and automatic interlocks are operating properly. Do not bypass or disarm any safety devices.
  • Page 7: High-Pressure Fluids

    PC Pedestal High-Pressure Fluids High-pressure fluids, unless they are safely contained, are extremely hazardous. Always relieve fluid pressure before adjusting or servicing high pressure equipment. A jet of high-pressure fluid can cut like a knife and cause serious bodily injury, amputation, or death.
  • Page 8: Fire Safety

    Chlorine “Chloro-” Bromine “Bromo-” Iodine “Iodo-” Check your material SDS or contact your material supplier for more information. If you must use halogenated hydrocarbon solvents, contact your Nordson representative for information about compatible Nordson components. 1617371-01 © 2022 Nordson Corporation...
  • Page 9: Action In The Event Of A Malfunction

    PC Pedestal Action in the Event of a Malfunction If a system or any equipment in a system malfunctions, shut off the system immediately and perform the following steps: • Disconnect and lock out system electrical power. Close hydraulic and pneumatic shutoff valves and relieve pressures.
  • Page 10: Description

    PC Pedestal Description The iTrax pedestal houses the PC used in iTrax systems for flexibility in establishing ® location of system controls interface. The pedestal comes with the following: • Power Disconnect • Power Supply • iTrax Software • Backup Battery •...
  • Page 11: Installation

    PC Pedestal Installation WARNING: Allow only qualified personnel to perform the following tasks. Follow the safety instructions in this document and all other related documentation. See Figure 2 and Figure 3 for placing and securing the pedestal. 17.80 in.
  • Page 12: Installing The Drain Line

    PC Pedestal Installing the Drain Line NOTE: For 120/220 Vac confirgurations only NOTE: Two hose fittings (a right angle and a straight one) and a length of PVC tubing are provided with the air conditioner. See Figure 4. 1. Choose the applicable fitting for the application and install it on the bottom of the air conditioning unit.
  • Page 13: Can Network Connection

    PC Pedestal CAN Network Connection See Figure 5 for location and wiring for the CAN network. 120/220 Vac Configuration See TB Detail 120/220 Vac TB Detail CANusb CAN Network SHLD SHLD SPARE NOTE: Air conditioner thermostat has a dial knob on the back of the unit for the setpoint.
  • Page 14: Power Connection

    10 iTrax® PC Pedestal Power Connection For installation, make the appropriate power connections and determine the best knockout size and location for power drop. Models 120 Vac 220 Vac 24 Vdc Supply Voltage 120 V, 1 PH, 50-60 Hz 220 V, 1 PH, 50-60 Hz...
  • Page 15: Repair

    PC Pedestal Repair WARNING: Allow only qualified personnel to perform the following tasks. Follow the safety instructions in this document and all other related documentation. Battery Replacement WARNING: When the backup battery is installed in a Class I, Division 2 Groups A B C D or Class I Zone 2 II C hazardous location, adhere to the following: •...
  • Page 16: Troubleshooting

    Allow only qualified personnel to perform the following tasks. Follow the safety instructions in this document and all other related documentation. These troubleshooting procedures cover only the most common problems. If you cannot solve a problem with the information given here, contact your local Nordson representative for help. Backup Battery...
  • Page 17: Parts

    PC Pedestal Parts NOTE: For software updates, refer to the iTrax PC Replacement guide and contact your Nordson representative. iTrax Pedestal Configurations Part Description Note 1621546 ASSEMBLY, iTRAX, PC, pedestal, 120 Vac 1621547 ASSEMBLY, iTRAX, PC, pedestal, 220 Vac...
  • Page 18: Itrax Datashare Installation Kits

    14 iTrax® PC Pedestal iTrax DataShare Installation Kits NOTE: Depending on the system requirements, both the Ethernet and Profinet installation kits are available for purchase. Part Description Note 1614723 KIT, DataShare, iTrax, Ethernet 1614724 KIT, DataShare, iTrax, Profinet 1617371-01 © 2022 Nordson Corporation...
  • Page 19 Amherst, Ohio, USA Nordson Authorized Representative in the EU Person authorized to compile the relevant technical documentation. Contact: Operations Manager Industrial Coating Systems Nordson Deutschland GmbH Heinrich-Hertz-StraBe 42-44 D-40699 Erkrath Nordson Corporation, 555 Jackson St, Amherst, Ohio, 44001. USA DOC12035-01...
  • Page 20 Engineering Manager Industrial Coating Systems Amherst, Ohio, USA Nordson Authorized Representative in the UK Contact: Technical Support Engineer Nordson UK Ltd.; Unit 10 Longstone Road Heald Green; Manchester, M22 5LB. England Nordson Corporation, 555 Jackson St, Amherst, Ohio, 44001. USA DOC12036-01...

Table of Contents